mirror of
https://github.com/FEX-Emu/linux.git
synced 2024-12-30 13:38:40 +00:00
can: c_can: Add support for TI DRA7 DCAN
DRA7 SoC has 2 CAN IPs. Provide compatible IDs and RAMINIT register data for both. Signed-off-by: Roger Quadros <rogerq@ti.com> Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
This commit is contained in:
parent
3973c526ae
commit
0f4da3a8da
@ -4,6 +4,7 @@ Bosch C_CAN/D_CAN controller Device Tree Bindings
|
||||
Required properties:
|
||||
- compatible : Should be "bosch,c_can" for C_CAN controllers and
|
||||
"bosch,d_can" for D_CAN controllers.
|
||||
Can be "ti,dra7-d_can".
|
||||
- reg : physical base address and size of the C_CAN/D_CAN
|
||||
registers map
|
||||
- interrupts : property with a value describing the interrupt
|
||||
|
@ -190,6 +190,18 @@ static const struct c_can_driver_data d_can_drvdata = {
|
||||
.id = BOSCH_D_CAN,
|
||||
};
|
||||
|
||||
static const struct raminit_bits dra7_raminit_bits[] = {
|
||||
[0] = { .start = 3, .done = 1, },
|
||||
[1] = { .start = 5, .done = 2, },
|
||||
};
|
||||
|
||||
static const struct c_can_driver_data dra7_dcan_drvdata = {
|
||||
.id = BOSCH_D_CAN,
|
||||
.raminit_num = ARRAY_SIZE(dra7_raminit_bits),
|
||||
.raminit_bits = dra7_raminit_bits,
|
||||
.raminit_pulse = true,
|
||||
};
|
||||
|
||||
static struct platform_device_id c_can_id_table[] = {
|
||||
{
|
||||
.name = KBUILD_MODNAME,
|
||||
@ -210,6 +222,7 @@ MODULE_DEVICE_TABLE(platform, c_can_id_table);
|
||||
static const struct of_device_id c_can_of_table[] = {
|
||||
{ .compatible = "bosch,c_can", .data = &c_can_drvdata },
|
||||
{ .compatible = "bosch,d_can", .data = &d_can_drvdata },
|
||||
{ .compatible = "ti,dra7-d_can", .data = &dra7_dcan_drvdata },
|
||||
{ /* sentinel */ },
|
||||
};
|
||||
MODULE_DEVICE_TABLE(of, c_can_of_table);
|
||||
|
Loading…
Reference in New Issue
Block a user