hwmon: (pmbus_core) Simplify sign extensions

Shift operations can be used for sign extensions. Use it.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
This commit is contained in:
Guenter Roeck 2011-09-28 11:36:20 -07:00
parent bc365a7f3c
commit 1af1f5313c

View File

@ -445,13 +445,8 @@ static long pmbus_reg2data_linear(struct pmbus_data *data,
exponent = data->exponent;
mantissa = (u16) sensor->data;
} else { /* LINEAR11 */
exponent = (sensor->data >> 11) & 0x001f;
mantissa = sensor->data & 0x07ff;
if (exponent > 0x0f)
exponent |= 0xffe0; /* sign extend exponent */
if (mantissa > 0x03ff)
mantissa |= 0xfffff800; /* sign extend mantissa */
exponent = ((s16)sensor->data) >> 11;
mantissa = ((s16)((sensor->data & 0x7ff) << 5)) >> 5;
}
val = mantissa;
@ -1628,7 +1623,7 @@ static void pmbus_find_attributes(struct i2c_client *client,
static int pmbus_identify_common(struct i2c_client *client,
struct pmbus_data *data)
{
int vout_mode = -1, exponent;
int vout_mode = -1;
if (pmbus_check_byte_register(client, 0, PMBUS_VOUT_MODE))
vout_mode = _pmbus_read_byte_data(client, 0, PMBUS_VOUT_MODE);
@ -1642,11 +1637,7 @@ static int pmbus_identify_common(struct i2c_client *client,
if (data->info->format[PSC_VOLTAGE_OUT] != linear)
return -ENODEV;
exponent = vout_mode & 0x1f;
/* and sign-extend it */
if (exponent & 0x10)
exponent |= ~0x1f;
data->exponent = exponent;
data->exponent = ((s8)(vout_mode << 3)) >> 3;
break;
case 1: /* VID mode */
if (data->info->format[PSC_VOLTAGE_OUT] != vid)