From 431386e783a3a6c8b7707bee32d18c353b8688b2 Mon Sep 17 00:00:00 2001 From: Akinobu Mita Date: Thu, 21 Jan 2016 01:07:31 +0900 Subject: [PATCH] iio: pressure: mpl115: fix temperature offset sign According to the datasheet, the resolusion of temperature sensor is -5.35 counts/C. Temperature ADC is 472 counts at 25C. (https://www.sparkfun.com/datasheets/Sensors/Pressure/MPL115A1.pdf NOTE: This is older revision, but this information is removed from the latest datasheet from nxp somehow) Temp [C] = (Tadc - 472) / -5.35 + 25 = (Tadc - 605.750000) * -0.186915888 So the correct offset is -605.750000. Signed-off-by: Akinobu Mita Acked-by: Peter Meerwald-Stadler Cc: Signed-off-by: Jonathan Cameron --- drivers/iio/pressure/mpl115.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/iio/pressure/mpl115.c b/drivers/iio/pressure/mpl115.c index f5ecd6e19f5d..a0d7deeac62f 100644 --- a/drivers/iio/pressure/mpl115.c +++ b/drivers/iio/pressure/mpl115.c @@ -117,7 +117,7 @@ static int mpl115_read_raw(struct iio_dev *indio_dev, *val = ret >> 6; return IIO_VAL_INT; case IIO_CHAN_INFO_OFFSET: - *val = 605; + *val = -605; *val2 = 750000; return IIO_VAL_INT_PLUS_MICRO; case IIO_CHAN_INFO_SCALE: