mirror of
https://github.com/FEX-Emu/linux.git
synced 2024-12-28 12:25:31 +00:00
cdc_ncm: toggle altsetting to force reset before setup
Some devices will silently fail setup unless they are reset first. This is necessary even if the data interface is already in altsetting 0, which it will be when the device is probed for the first time. Briefly toggling the altsetting forces a function reset regardless of the initial state. This fixes a setup problem observed on a number of Huawei devices, appearing to operate in NTB-32 mode even if we explicitly set them to NTB-16 mode. Signed-off-by: Bjørn Mork <bjorn@mork.no> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
1666984c86
commit
48906f62c9
@ -837,7 +837,11 @@ int cdc_ncm_bind_common(struct usbnet *dev, struct usb_interface *intf, u8 data_
|
||||
|
||||
iface_no = ctx->data->cur_altsetting->desc.bInterfaceNumber;
|
||||
|
||||
/* reset data interface */
|
||||
/* Reset data interface. Some devices will not reset properly
|
||||
* unless they are configured first. Toggle the altsetting to
|
||||
* force a reset
|
||||
*/
|
||||
usb_set_interface(dev->udev, iface_no, data_altsetting);
|
||||
temp = usb_set_interface(dev->udev, iface_no, 0);
|
||||
if (temp) {
|
||||
dev_dbg(&intf->dev, "set interface failed\n");
|
||||
|
Loading…