mirror of
https://github.com/FEX-Emu/linux.git
synced 2024-12-22 01:10:28 +00:00
V4L/DVB: em28xx-input: Don't generate one debug message for every get_key read
Instead of generating one printk for every IR read, prints it only when count is different from the last count. While here, as this code is called on every 100ms during the runtime lifetime, do some performance optimization, assuming that, under normal circumstances, it is unlikely that the driver would get a new key/key repeat on every poll. Signed-off-by: Mauro Carvalho Chehab <mchehab@redhat.com>
This commit is contained in:
parent
a469585b1c
commit
603044d883
@ -292,18 +292,15 @@ static void em28xx_ir_handle_key(struct em28xx_IR *ir)
|
||||
|
||||
/* read the registers containing the IR status */
|
||||
result = ir->get_key(ir, &poll_result);
|
||||
if (result < 0) {
|
||||
if (unlikely(result < 0)) {
|
||||
dprintk("ir->get_key() failed %d\n", result);
|
||||
return;
|
||||
}
|
||||
|
||||
dprintk("ir->get_key result tb=%02x rc=%02x lr=%02x data=%02x%02x\n",
|
||||
poll_result.toggle_bit, poll_result.read_count,
|
||||
ir->last_readcount, poll_result.rc_address,
|
||||
poll_result.rc_data[0]);
|
||||
|
||||
if (poll_result.read_count > 0 &&
|
||||
poll_result.read_count != ir->last_readcount) {
|
||||
if (unlikely(poll_result.read_count != ir->last_readcount)) {
|
||||
dprintk("%s: toggle: %d, count: %d, key 0x%02x%02x\n", __func__,
|
||||
poll_result.toggle_bit, poll_result.read_count,
|
||||
poll_result.rc_address, poll_result.rc_data[0]);
|
||||
if (ir->full_code)
|
||||
ir_keydown(ir->input,
|
||||
poll_result.rc_address << 8 |
|
||||
@ -313,17 +310,17 @@ static void em28xx_ir_handle_key(struct em28xx_IR *ir)
|
||||
ir_keydown(ir->input,
|
||||
poll_result.rc_data[0],
|
||||
poll_result.toggle_bit);
|
||||
}
|
||||
|
||||
if (ir->dev->chip_id == CHIP_ID_EM2874)
|
||||
/* The em2874 clears the readcount field every time the
|
||||
register is read. The em2860/2880 datasheet says that it
|
||||
is supposed to clear the readcount, but it doesn't. So with
|
||||
the em2874, we are looking for a non-zero read count as
|
||||
opposed to a readcount that is incrementing */
|
||||
ir->last_readcount = 0;
|
||||
else
|
||||
ir->last_readcount = poll_result.read_count;
|
||||
if (ir->dev->chip_id == CHIP_ID_EM2874)
|
||||
/* The em2874 clears the readcount field every time the
|
||||
register is read. The em2860/2880 datasheet says that it
|
||||
is supposed to clear the readcount, but it doesn't. So with
|
||||
the em2874, we are looking for a non-zero read count as
|
||||
opposed to a readcount that is incrementing */
|
||||
ir->last_readcount = 0;
|
||||
else
|
||||
ir->last_readcount = poll_result.read_count;
|
||||
}
|
||||
}
|
||||
|
||||
static void em28xx_ir_work(struct work_struct *work)
|
||||
|
Loading…
Reference in New Issue
Block a user