mirror of
https://github.com/FEX-Emu/linux.git
synced 2024-12-27 03:47:43 +00:00
ARM: EXYNOS: Make s3c_device_i2c0 always use id 0
This patch removes compatibility definitions added long time ago when clock ids were used instead of devnames that were needed for platforms with only one i2c controller with id -1 (some s3c24xx's). Because currently devname field is used for matching device instances to clocks and if no devname is provided (as in clock-s3c2412.c and common-s3c2443.c for i2c clock, both in arch/arm/mach-s3c24xx) the clock is being matched only by name, so s3c_device_i2c0 can always have id 0. This patch solves the issue with i2c0 broken on boards where its the only i2c controller used, tested on Origen. Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com> Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
This commit is contained in:
parent
fa089de7d5
commit
62ef4a5d7a
@ -138,11 +138,7 @@ static struct clk init_clocks_off[] = {
|
||||
.ctrlbit = S3C_CLKCON_PCLK_TSADC,
|
||||
}, {
|
||||
.name = "i2c",
|
||||
#ifdef CONFIG_S3C_DEV_I2C1
|
||||
.devname = "s3c2440-i2c.0",
|
||||
#else
|
||||
.devname = "s3c2440-i2c",
|
||||
#endif
|
||||
.parent = &clk_p,
|
||||
.enable = s3c64xx_pclk_ctrl,
|
||||
.ctrlbit = S3C_CLKCON_PCLK_IIC,
|
||||
|
@ -486,11 +486,7 @@ static struct resource s3c_i2c0_resource[] = {
|
||||
|
||||
struct platform_device s3c_device_i2c0 = {
|
||||
.name = "s3c2410-i2c",
|
||||
#ifdef CONFIG_S3C_DEV_I2C1
|
||||
.id = 0,
|
||||
#else
|
||||
.id = -1,
|
||||
#endif
|
||||
.num_resources = ARRAY_SIZE(s3c_i2c0_resource),
|
||||
.resource = s3c_i2c0_resource,
|
||||
};
|
||||
|
Loading…
Reference in New Issue
Block a user