myri10ge: fix tx ring size in ethtool -g

Fix tx ring size reported via ethtool -g.

Signed-off-by: Brice Goglin <brice@myri.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Brice Goglin 2009-04-16 17:56:57 -07:00 committed by David S. Miller
parent 9713107918
commit 6498be3fba

View File

@ -1696,7 +1696,7 @@ myri10ge_get_ringparam(struct net_device *netdev,
ring->rx_mini_max_pending = mgp->ss[0].rx_small.mask + 1;
ring->rx_max_pending = mgp->ss[0].rx_big.mask + 1;
ring->rx_jumbo_max_pending = 0;
ring->tx_max_pending = mgp->ss[0].rx_small.mask + 1;
ring->tx_max_pending = mgp->ss[0].tx.mask + 1;
ring->rx_mini_pending = ring->rx_mini_max_pending;
ring->rx_pending = ring->rx_max_pending;
ring->rx_jumbo_pending = ring->rx_jumbo_max_pending;