mirror of
https://github.com/FEX-Emu/linux.git
synced 2024-12-23 18:07:03 +00:00
parisc: Prevent panic at system halt
When issuing a "shutdown -h now", the reboot syscall calls kernel_halt() which shouldn't return, otherwise one gets this panic: reboot: System halted Kernel panic - not syncing: Attempted to kill init! exitcode=0x00000000 CPU: 0 PID: 1 Comm: systemd-shutdow Not tainted 4.16.0-32bit+ #560 Backtrace: [<1018a694>] show_stack+0x18/0x28 [<106e68a8>] dump_stack+0x80/0x10c [<101a4df8>] panic+0xfc/0x290 [<101a90b8>] do_exit+0x73c/0x914 [<101c7e38>] SyS_reboot+0x190/0x1d4 [<1017e444>] syscall_exit+0x0/0x14 Fix it by letting machine_halt() call machine_power_off() which doesn't return. Signed-off-by: Helge Deller <deller@gmx.de>
This commit is contained in:
parent
71d577db01
commit
6769828703
@ -112,14 +112,6 @@ void machine_restart(char *cmd)
|
||||
|
||||
}
|
||||
|
||||
void machine_halt(void)
|
||||
{
|
||||
/*
|
||||
** The LED/ChassisCodes are updated by the led_halt()
|
||||
** function, called by the reboot notifier chain.
|
||||
*/
|
||||
}
|
||||
|
||||
void (*chassis_power_off)(void);
|
||||
|
||||
/*
|
||||
@ -158,6 +150,11 @@ void machine_power_off(void)
|
||||
void (*pm_power_off)(void);
|
||||
EXPORT_SYMBOL(pm_power_off);
|
||||
|
||||
void machine_halt(void)
|
||||
{
|
||||
machine_power_off();
|
||||
}
|
||||
|
||||
void flush_thread(void)
|
||||
{
|
||||
/* Only needs to handle fpu stuff or perf monitors.
|
||||
|
Loading…
Reference in New Issue
Block a user