brcm80211: smac: set interface down on reset

This change marks interface as down on reset, otherwise the driver can't
reinitialize itself properly.

Without the change a transient problem turns out to be critical and leads
to inavailability to reset the driver without brcmsmac module unload/load
cycle:

    ieee80211 phy0: wl0: PSM microcode watchdog fired at 5993 (seconds). Resetting.
    brcms_c_dpc : PSM Watchdog, chipid 0xa8d9, chiprev 0x1
    ieee80211 phy0: wl0: fatal error, reinitializing
    ieee80211 phy0: Hardware restart was requested
    ieee80211 phy0: brcms_ops_start: brcms_up() returned -19

Signed-off-by: Vladimir Zapolskiy <vz@mleia.com>
Cc: Arend van Spriel <arend@broadcom.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
Vladimir Zapolskiy 2012-08-05 00:29:07 +03:00 committed by John W. Linville
parent 4fc79db178
commit ea2d218308

View File

@ -1233,6 +1233,9 @@ uint brcms_reset(struct brcms_info *wl)
/* dpc will not be rescheduled */
wl->resched = false;
/* inform publicly that interface is down */
wl->pub->up = false;
return 0;
}