clk: ux500: fix erroneous bit assignment

Due to a typo or similar, the peripheral group 2 clock 11
gate was set to bit 1 instead of bit 11. We need to fix this
to be able to set the correct enable bit in the device tree:
when trying to correct the bit assignment in the device tree,
the system would hang.

Cc: Mike Turquette <mturquette@linaro.org>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
This commit is contained in:
Linus Walleij 2013-10-18 10:56:14 +02:00
parent 84873cb773
commit f5ff9a115e

View File

@ -339,7 +339,7 @@ void u8500_of_clk_init(u32 clkrst1_base, u32 clkrst2_base, u32 clkrst3_base,
clk = clk_reg_prcc_pclk("p2_pclk11", "per2clk", clkrst2_base,
BIT(11), 0);
PRCC_PCLK_STORE(clk, 2, 1);
PRCC_PCLK_STORE(clk, 2, 11);
clk = clk_reg_prcc_pclk("p2_pclk12", "per2clk", clkrst2_base,
BIT(12), 0);