Commit Graph

26 Commits

Author SHA1 Message Date
Greg Kroah-Hartman
df47c0a638 Fifth set of IIO fixes for the 4.11 cycle.
As these are rather late in the cycle, they may sneak over into 4.12.
 There is a fix for a regression caused by another fix (hid sensors
 hardware seems to vary a lot in how various corner cases are handled).
 
 * ad7303
   - fix channel description. Numeric values were being passed as characters
   presumably leading to garbage from the userspace interface.
 * as3935
   - the write data macro was wrong so fix it.
 * bmp280
   - incorrect handling of negative values as being unsigned broke humidity
   calculation.
 * hid-sensor
   - Restore the poll and hysteresis values after resume as some hardware
   doesn't do it.
 * stm32-trigger
   - buglet in reading the sampling frequency
 -----BEGIN PGP SIGNATURE-----
 
 iQJFBAABCAAvFiEEbilms4eEBlKRJoGxVIU0mcT0FogFAljw8ScRHGppYzIzQGtl
 cm5lbC5vcmcACgkQVIU0mcT0FojZvBAAh8K9e+3ObpS6/0wj26/XsakiFn4v2ah0
 xKUnafxAVVxU3AU01IJ3CtNdIMyqMwpnB+PvnpgDzZw749QrYKPsBIzheK64eabe
 fzA34X5MWGLwUdOXpfEB0xvsylWjJrqsf1rahgZjiUKkPeZe9EwzPM/fP1sEl5gu
 p+vfSMckboFaKheoQwnWMUTBp0HK+nbFpcSBzljX68u+epiXpDGrjuZC8NJ3JuBn
 Bloz9AhDliIn477H7mIUTXBbt3ixLIDiJ7haQuTNlagosPoUtCBpwY2O9mZ7VRVs
 wM62h7/F170077ReQJRjlfck+7uHoIgDeS46w5UYTzA1HJLxs+veO5xv3VOtHIUg
 BZ+mibQyIUBrFeyYDVbeUpBTffiU6rA+yiM4WFwUFabl7t7rlG0NhLEx7OIQcFMm
 l8u/5JUoJcoykaO8c9Jx5XtrgkXq+rCWVAmhjHqUDAlvsMa6pJWEyqgaVcQeIbdw
 ns9ppJRlOmEst7lMab9TI7BJp3oCIH6uRmctbme42Rw8XgDFdltxqkxmjB8d+cDC
 Q0INhNJN1jRgz6rT6lkxVhAYKtaP5T8qZeliT4MO1E59ggOVSSf8zuhjrEMUK397
 Tu/k7fmATtiKSG+blwYZVRC3+ixh/oKZsvfwZ4O+mFJyhQ616nKMYAywoaZcM8WT
 Z1ABipUDwsE=
 =H5KS
 -----END PGP SIGNATURE-----

Merge tag 'iio-fixes-for-4.11e' of git://git.kernel.org/pub/scm/linux/kernel/git/jic23/iio into staging-next

Jonathan writes:

Fifth set of IIO fixes for the 4.11 cycle.

As these are rather late in the cycle, they may sneak over into 4.12.
There is a fix for a regression caused by another fix (hid sensors
hardware seems to vary a lot in how various corner cases are handled).

* ad7303
  - fix channel description. Numeric values were being passed as characters
  presumably leading to garbage from the userspace interface.
* as3935
  - the write data macro was wrong so fix it.
* bmp280
  - incorrect handling of negative values as being unsigned broke humidity
  calculation.
* hid-sensor
  - Restore the poll and hysteresis values after resume as some hardware
  doesn't do it.
* stm32-trigger
  - buglet in reading the sampling frequency
2017-04-18 19:38:38 +02:00
Srinivas Pandruvada
c94f5806cd iio: hid-sensor: Fix unbalanced pm_runtime_enable error
When a hid sensor module is removed and modprobed again we see
error for unbalanced pm_runtime. This issue is caused by not
deactivating runtime PM on removal. So on modprobe again when
activated again, this will print this error.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2017-04-08 15:36:47 +01:00
Srinivas Pandruvada
5d9854eaea iio: hid-sensor: Store restore poll and hysteresis on S3
This change undo the change done by 'commit 3bec247474
("iio: hid-sensor-trigger: Change get poll value function order to avoid
sensor properties losing after resume from S3")' as this breaks some
USB/i2c sensor hubs.

Instead of relying on HW for restoring poll and hysteresis, driver stores
and restores on resume (S3). In this way user space modified settings are
not lost for any kind of sensor hub behavior.

In this change, whenever user space modifies sampling frequency or
hysteresis driver will get the feature value from the hub and store in the
per device hid_sensor_common data structure. On resume callback from S3,
system will set the feature to sensor hub, if user space ever modified the
feature value.

Fixes: 3bec247474 ("iio: hid-sensor-trigger: Change get poll value function order to avoid sensor properties losing after resume from S3")
Reported-by: Ritesh Raj Sarraf <rrs@researchut.com>
Tested-by: Ritesh Raj Sarraf <rrs@researchut.com>
Tested-by: Song, Hongyan <hongyan.song@intel.com>
Cc: stable@vger.kernel.org
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2017-04-08 15:13:36 +01:00
Song Hongyan
3bec247474 iio: hid-sensor-trigger: Change get poll value function order to avoid sensor properties losing after resume from S3
In function _hid_sensor_power_state(), when hid_sensor_read_poll_value()
is called, sensor's all properties will be updated by the value from
sensor hardware/firmware.
In some implementation, sensor hardware/firmware will do a power cycle
during S3. In this case, after resume, once hid_sensor_read_poll_value()
is called, sensor's all properties which are kept by driver during S3
will be changed to default value.
But instead, if a set feature function is called first, sensor
hardware/firmware will be recovered to the last status. So change the
sensor_hub_set_feature() calling order to behind of set feature function
to avoid sensor properties lose.

Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2017-03-05 10:26:47 +00:00
Arnd Bergmann
2e1f44d8a7 iio: hid-sensors: avoid unused function warning
A small rework of the PM code in this driver introduced a harmless
warning when CONFIG_PM_SLEEP is not set:

drivers/iio/common/hid-sensors/hid-sensor-trigger.c:212:12: error: 'hid_sensor_resume' defined but not used [-Werror=unused-function]

This removes the #ifdef and instead marks all three PM functions
as __maybe_unused, which covers all possible cases and is harder
to get wrong.

Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Fixes: 7f6cf74145 ("iio: hid-sensors: use asynchronous resume")
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2016-08-29 19:54:08 +01:00
Srinivas Pandruvada
7f6cf74145 iio: hid-sensors: use asynchronous resume
Some platforms power off sensor hubs during S3 suspend, which will require
longer time to resume. This hurts system resume time, so resume
asynchronously.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2016-08-21 20:12:32 +01:00
Slawomir Stepien
d23057e0ca iio: common: hid-sensors: use tab for indention
This fixes the error reported by checkpatch.pl:

ERROR: code indent should use tabs where possible

Signed-off-by: Slawomir Stepien <sst@poczta.fm>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2016-04-16 13:39:26 +01:00
Srinivas Pandruvada
1e25aa9641 hid-sensor: Fix suspend/resume delay
By default all the sensors are runtime suspended state (lowest power
state). During Linux suspend process, all the run time suspended
devices are resumed and then suspended. This caused all sensors to
power up and introduced delay in suspend time, when we introduced
runtime PM for HID sensors. The opposite process happens during resume
process.

To fix this, we do powerup process of the sensors only when the request
is issued from user (raw or tiggerred). In this way when runtime,
resume calls for powerup it will simply return as this will not match
user requested state.

Note this is a regression fix as the increase in suspend / resume
times can be substantial (report of 8 seconds on Len's laptop!)

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Tested-by: Len Brown <len.brown@intel.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2015-06-02 22:15:26 +01:00
Jiri Kosina
2e455c27bd Merge branch 'for-4.1/sensor-hub' into for-linus
Conflicts:
	drivers/iio/common/hid-sensors/hid-sensor-trigger.c
	include/linux/hid-sensor-hub.h
2015-04-13 23:43:34 +02:00
Srinivas Pandruvada
3950e03389 HID: hid-sensor-hub: Enhance feature report set API
Current API only allows setting one offset in the field. This API
is extended to set multiple offsets in the field report.
Also update parameters in the users of this API.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reviewed-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-02-23 15:20:00 +01:00
Srinivas Pandruvada
6adc83fca7 HID: hid-sensor-hub: Enhance get feature report API
Some hid sensor feature report can contain more than one reports.
This API can now support receiving multiple values from the feature
report.
Also update the parameters in the users of this API.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Acked-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2015-02-23 15:19:49 +01:00
Srinivas Pandruvada
2b89635e9a iio: hid_sensor_hub: Common PM functions
To improvement power and performance, both regular and run time callbacks
are introduced. Because of auto suspend delay, two consecutive read
don't have to go through full power on/off procedure. The auto suspend
time can be adjusted using regular power attributes of PM sysfs.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2015-01-25 22:55:39 +00:00
Srinivas Pandruvada
55a6f9ddfd iio: hid_sensor_hub: Fix indio_dev->trig assignment
This can result in wrong reference count for trigger device, call
iio_trigger_get to increment reference.
Refer to http://www.spinics.net/lists/linux-iio/msg13669.html for discussion
with Jonathan.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Cc: Stable@vger.kernel.org
2014-08-25 21:48:39 +01:00
Greg Kroah-Hartman
e28642c04a First set of IIO fixes for the 3.16 cycle.
A mixed bag of fixes, many of which feel just to late for 3.15.
 
 * hid sensors - some devices need a feature report request in order to
   change power state.  This isn't part of the spec, but has been observed
   on several devices and does no harm to others.
 * mpl3115 has had two errors in the buffer description fixed. The presure is
   signed, not unsigned and the temperature has 12 bits rather than 16.
   These could lead to incorrect interpretation of the data in userspace.
 * tsl2x7x - the high byte of the proximity thresholds should be written along
   with the low byte (which was). This could lead to interesting results
   with large thresholds.
 * twl4030 - a flag to specify processed values were required was not set
   when initializing a reading.  As such values returned were in an unknown
   state. Fixed by simply initializing it appropriately.
 * IIO_SIMPLE_DUMMY_BUFFER did not select IIO_BUFFER leading to randconfig
   build errors.
 * ak8975 was applying an unwanted le16_to_cpu conversion as the i2c framework
   already performs one.  As such for big endian systems, the bytes would be
   in the wrong order in the magnetic field measurements reported.
 * mxs-lradc - the controllable voltage dividers were not enabled / disabled for
   later channels than the first one during conversion.
 * at91_adc error handling returned -ENOMEM in a u8. Return value of
   at91_adc_get_trigger_value_by_name changed to int thus allowing -ENOMEM and
   also original values to be returned.
 * mcb - mcb_request_mem returns and ERR_PTR but the caller was checking for
   NULL to detect an error.
 -----BEGIN PGP SIGNATURE-----
 Version: GnuPG v2
 
 iQIcBAABAgAGBQJTnLYyAAoJEFSFNJnE9BaI6r4QAK22hjl1J3xoWwOPUJhfJ5Hh
 VTjwO1OxwQ1XtUN5WneeJM73eu6moXD/avG2NbX4orAkNjSXKL6+/3WAds/rYMj2
 0vPiJsKsGBBlhu2w2RU80xVOPT2/XXIH3bYWDiUlr/i6DLEh8mU3kKX/yZzF+cIn
 hheYnOHZzLqGH8JircScEJv+B06svZtlfoDeLYaKY03HupTvEH95mvCSZk71PxZb
 A+7Qb3nDlZrpLBFKj4L5x15MIoEgopID2pX0kHLNY2DE1sopr2Z+FgSa3u/wtSEx
 k/ViyHPRk1mjTrQ92RMmTF5lMts6JFCmMgpPCNmcSyRKt6Fe6KcCMiWIlSs9I69i
 6KAIes5XpP7Qti5Yd4gi70uiq7fL1hR18Yhzv6IdmNdS8iJhk53YiWDYiYBgXwWS
 rcOva4NsaoeLYUdNJZRtap3RLsQRKAxg7HNhL+G88rr3wCsA0P7rb6BMdFK+3MiS
 BDcYe8mHIzX9tJZa4EU8kOdr+aphQeDt1nH4aZDWT3J7fo6RWrWcPMWFAcx+1jp3
 VVDL6Jn8WIuxYIDFznSQ6T6tvsvuqPgCqOA0ygfzvruo3m/oWvTT/+i2YFotGH3Y
 7Mlw7TACAmcuZStBLg6R0R1fD39zpfp4/+GNRxFaaB8otMPyrbizb0HBcaksQCp0
 0MTbFSjuAlXZ3NhVIm2O
 =RuB2
 -----END PGP SIGNATURE-----

Merge tag 'iio-fixes-for-3.16a' of git://git.kernel.org/pub/scm/linux/kernel/git/jic23/iio into staging-linus

Jonathan writes:

First set of IIO fixes for the 3.16 cycle.

A mixed bag of fixes, many of which feel just to late for 3.15.

* hid sensors - some devices need a feature report request in order to
  change power state.  This isn't part of the spec, but has been observed
  on several devices and does no harm to others.
* mpl3115 has had two errors in the buffer description fixed. The presure is
  signed, not unsigned and the temperature has 12 bits rather than 16.
  These could lead to incorrect interpretation of the data in userspace.
* tsl2x7x - the high byte of the proximity thresholds should be written along
  with the low byte (which was). This could lead to interesting results
  with large thresholds.
* twl4030 - a flag to specify processed values were required was not set
  when initializing a reading.  As such values returned were in an unknown
  state. Fixed by simply initializing it appropriately.
* IIO_SIMPLE_DUMMY_BUFFER did not select IIO_BUFFER leading to randconfig
  build errors.
* ak8975 was applying an unwanted le16_to_cpu conversion as the i2c framework
  already performs one.  As such for big endian systems, the bytes would be
  in the wrong order in the magnetic field measurements reported.
* mxs-lradc - the controllable voltage dividers were not enabled / disabled for
  later channels than the first one during conversion.
* at91_adc error handling returned -ENOMEM in a u8. Return value of
  at91_adc_get_trigger_value_by_name changed to int thus allowing -ENOMEM and
  also original values to be returned.
* mcb - mcb_request_mem returns and ERR_PTR but the caller was checking for
  NULL to detect an error.
2014-06-18 10:41:08 -07:00
Archana Patni
c0a36f08f4 iio: hid-sensors: Get feature report from sensor hub after changing power state
Some sensor hubs require a get feature report call to be issued soon after
changing the power state of the sensor. Without this, the sensor remains in
the current state. This patch adds a call soon after the power state.

This is retained as a generic call across all sensor hubs since the behavior
has been noticed on more than one implementation.

Signed-off-by: Archana Patni <archana.patni@intel.com>
Signed-off-by: Subramony Sesha <subramony.sesha@intel.com>
Reviewed-by: Srinivas Pandruvada <srinivas.pandruvada@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2014-05-29 17:38:33 +01:00
Srinivas Pandruvada
56ff6be608 iio: hid-sensors: Add API to power on/off
Added an API to allow client drivers to turn ON and OFF sensors for
quick read. Added data_read as counting varaible instead of boolean,
so that sensor is powered off only when last user released it.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2014-05-05 10:59:49 +01:00
Srinivas Pandruvada
1a214ae5d1 iio: hid-sensor-hub: Remove hard coded indexes
Remove the hard coded indexes, instead search for usage id and
use the index to set the power and report state.
This will fix issue, where the report descriptor doesn't contain
the full list of possible selector for power and report state.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Acked-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
2014-02-17 15:09:47 +01:00
Srinivas Pandruvada
751d17e23a iio: hid-sensors: Fix power and report state
In the original HID sensor hub firmwares all Named array enums were
to 0-based. But the most recent hub implemented as 1-based,
because of the implementation by one of the major OS vendor.
Using logical minimum for the field as the base of enum. So we add
logical minimum to the selector values before setting those fields.
Some sensor hub FWs already changed logical minimum from 0 to 1
to reflect this and hope every other vendor will follow.
There is no easy way to add a common HID quirk for NAry elements,
even if the standard specifies these field as NAry, the collection
used to describe selectors is still just "logical".

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2013-12-02 21:05:32 +00:00
Srinivas Pandruvada
ec7f68e07b iio: hid_Sensors: fix crash during trigger unregister
We can't store the trigger instance created by iio_trigger_alloc, in
trig field of iio_device structure. This needs to be stored in the
driver private data. Othewise it can result in crash during module
unload. Hence created a trig_ptr in the common data structure
for each HID sensor IIO driver and storing here.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2013-11-02 19:07:06 +00:00
Srinivas Pandruvada
7d3c192df0 IIO: call sensor hub open close function
Call hid_sensor_hub_device_open when user space opens device and call
hid_sensor_hub_device_close when device is closed. This helps in
saving power.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2013-10-01 16:19:08 +01:00
Lars-Peter Clausen
1e9663c62b iio:trigger: Introduce iio_tigger_{set,get}_drvdata
Introduce iio_tigger_{set,get}_drvdata which allows to attach driver specific
data to a trigger. The functions wrap access to the triggers private_data field
and all current users are updated to use iio_tigger_{set,get}_drvdata instead of
directly accessing the private_data field. This is the first step towards
removing the private_data field from the iio_trigger struct.

The following coccinelle script has been used to update the drivers:
<smpl>
@@
struct iio_trigger *trigger;
expression priv;
@@
-trigger->private_data = priv
+iio_trigger_set_drv_data(trigger, priv)

@@
struct iio_trigger *trigger;
@@
-trigger->private_data
+iio_trigger_get_drv_data(trigger)
</smpl>

Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2013-03-25 21:06:09 +00:00
Alexander Holler
e07c6d170c hid: iio: rename struct hid_sensor_iio_common to hid_sensor_common
The structure with common attributes for hid-sensors isn't specific
to the iio-subsystem, so rename it to hid_sensor_common.

Signed-off-by: Alexander Holler <holler@ahsoftware.de>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2013-01-06 11:48:11 +00:00
Alexander Holler
2974cdf293 iio: merge hid-sensor-attributes.h into hid-sensor-hub.h
The stuff in hid-sensor-attributes.h is needed by every piece which
uses hid-sensor-hub and merging it into hid-sensor-hub.h makes it accessible
from outside the iio subdirectory.

Signed-off-by: Alexander Holler <holler@ahsoftware.de>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2013-01-06 11:43:37 +00:00
Kirill A. Shutemov
69bcd3bf40 iio: hid-sensors: convert HID_SENSOR_ENUM_BASE_QUIRKS to bool
It's non-sense to use tristate for the option, it's bool.

Signed-off-by: Kirill A. Shutemov <kirill.shutemov@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2012-11-17 10:15:41 +00:00
Srinivas Pandruvada
f07b60b7c3 iio: hid-sensors: Prevent crash during hot-unplug
When hid sensor hub is unplugged, there is a crash in
iio_device_unregister_trigger_consumer.
In a typical IIO driver when remove is called, it will unregister and free
trigger and then it will call iio_device_free.
The function iio_trigger_free() will free the allocated memory for trigger.
If this trigger was assigned to iio_dev->trig, then it should be set to NULL.
Othewise when iio_device_free() is called later, it finally calls
iio_device_unregsister_trigger(), which checks for
       if (indio_dev->trig)
                iio_trigger_put(indio_dev->trig);
If indio_dev->trig is not set to NULL, it calls iio_trigger_put on a bad
pointer causing crash.
This scenerio can happen in any driver, which is storing trigger pointer in
iio_dev structure and following current procedure during remove.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2012-09-22 10:07:34 +01:00
srinivas pandruvada
73c6768b71 iio: hid-sensors: Common attribute and trigger
This patch contains the common code, which is used by all HID sensors.
There are some common set of attributes, which every hid sensor
needs it. This patch contains all such attributes processing.
Also the trigger interface is common among all HID sensors. This
patch contains common trigger functions utilized by all HID sensors.

Signed-off-by: srinivas pandruvada <srinivas.pandruvada@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2012-09-06 19:20:11 +01:00