mirror of
https://github.com/FEX-Emu/linux.git
synced 2025-01-10 03:20:49 +00:00
0083b91dac
For now, we only boost the fan speed to the maximum and auto-mode when hitting the FAN_BOOST threshold and halt the computer when it reaches the shutdown temperature. The downclock and critical thresholds do nothing. On nv43:50 and nva3+, temperature is polled because of the limited hardware. I'll improve the nva3+ situation by implementing alarm management in PDAEMON whenever I can but polling once every second shouldn't be such a problem. v2 (Ben Skeggs): - rebased v3: fixed false-detections and threshold reprogrammation handling on nv50:nvc0 Signed-off-by: Ben Skeggs <bskeggs@redhat.com> Signed-off-by: Martin Peres <martin.peres@labri.fr> |
||
---|---|---|
.. | ||
drm | ||
stub | ||
vga | ||
Makefile |