mirror of
https://github.com/FEX-Emu/linux.git
synced 2024-12-27 03:47:43 +00:00
1ca5b9d218
This adds serial number support to the OLPC battery driver. Signed-off-by: David Woodhouse <dwmw2@infradead.org> Signed-off-by: Andres Salomon <dilinger@debian.org> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
353 lines
9.1 KiB
C
353 lines
9.1 KiB
C
/*
|
|
* Battery driver for One Laptop Per Child board.
|
|
*
|
|
* Copyright © 2006 David Woodhouse <dwmw2@infradead.org>
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License version 2 as
|
|
* published by the Free Software Foundation.
|
|
*/
|
|
|
|
#include <linux/module.h>
|
|
#include <linux/err.h>
|
|
#include <linux/platform_device.h>
|
|
#include <linux/power_supply.h>
|
|
#include <linux/jiffies.h>
|
|
#include <linux/sched.h>
|
|
#include <asm/olpc.h>
|
|
|
|
|
|
#define EC_BAT_VOLTAGE 0x10 /* uint16_t, *9.76/32, mV */
|
|
#define EC_BAT_CURRENT 0x11 /* int16_t, *15.625/120, mA */
|
|
#define EC_BAT_ACR 0x12
|
|
#define EC_BAT_TEMP 0x13 /* uint16_t, *100/256, °C */
|
|
#define EC_AMB_TEMP 0x14 /* uint16_t, *100/256, °C */
|
|
#define EC_BAT_STATUS 0x15 /* uint8_t, bitmask */
|
|
#define EC_BAT_SOC 0x16 /* uint8_t, percentage */
|
|
#define EC_BAT_SERIAL 0x17 /* uint8_t[6] */
|
|
#define EC_BAT_EEPROM 0x18 /* uint8_t adr as input, uint8_t output */
|
|
#define EC_BAT_ERRCODE 0x1f /* uint8_t, bitmask */
|
|
|
|
#define BAT_STAT_PRESENT 0x01
|
|
#define BAT_STAT_FULL 0x02
|
|
#define BAT_STAT_LOW 0x04
|
|
#define BAT_STAT_DESTROY 0x08
|
|
#define BAT_STAT_AC 0x10
|
|
#define BAT_STAT_CHARGING 0x20
|
|
#define BAT_STAT_DISCHARGING 0x40
|
|
|
|
#define BAT_ERR_INFOFAIL 0x02
|
|
#define BAT_ERR_OVERVOLTAGE 0x04
|
|
#define BAT_ERR_OVERTEMP 0x05
|
|
#define BAT_ERR_GAUGESTOP 0x06
|
|
#define BAT_ERR_OUT_OF_CONTROL 0x07
|
|
#define BAT_ERR_ID_FAIL 0x09
|
|
#define BAT_ERR_ACR_FAIL 0x10
|
|
|
|
#define BAT_ADDR_MFR_TYPE 0x5F
|
|
|
|
/*********************************************************************
|
|
* Power
|
|
*********************************************************************/
|
|
|
|
static int olpc_ac_get_prop(struct power_supply *psy,
|
|
enum power_supply_property psp,
|
|
union power_supply_propval *val)
|
|
{
|
|
int ret = 0;
|
|
uint8_t status;
|
|
|
|
switch (psp) {
|
|
case POWER_SUPPLY_PROP_ONLINE:
|
|
ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &status, 1);
|
|
if (ret)
|
|
return ret;
|
|
|
|
val->intval = !!(status & BAT_STAT_AC);
|
|
break;
|
|
default:
|
|
ret = -EINVAL;
|
|
break;
|
|
}
|
|
return ret;
|
|
}
|
|
|
|
static enum power_supply_property olpc_ac_props[] = {
|
|
POWER_SUPPLY_PROP_ONLINE,
|
|
};
|
|
|
|
static struct power_supply olpc_ac = {
|
|
.name = "olpc-ac",
|
|
.type = POWER_SUPPLY_TYPE_MAINS,
|
|
.properties = olpc_ac_props,
|
|
.num_properties = ARRAY_SIZE(olpc_ac_props),
|
|
.get_property = olpc_ac_get_prop,
|
|
};
|
|
|
|
static char bat_serial[17]; /* Ick */
|
|
|
|
/*********************************************************************
|
|
* Battery properties
|
|
*********************************************************************/
|
|
static int olpc_bat_get_property(struct power_supply *psy,
|
|
enum power_supply_property psp,
|
|
union power_supply_propval *val)
|
|
{
|
|
int ret = 0;
|
|
int16_t ec_word;
|
|
uint8_t ec_byte;
|
|
uint64_t ser_buf;
|
|
|
|
ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &ec_byte, 1);
|
|
if (ret)
|
|
return ret;
|
|
|
|
/* Theoretically there's a race here -- the battery could be
|
|
removed immediately after we check whether it's present, and
|
|
then we query for some other property of the now-absent battery.
|
|
It doesn't matter though -- the EC will return the last-known
|
|
information, and it's as if we just ran that _little_ bit faster
|
|
and managed to read it out before the battery went away. */
|
|
if (!(ec_byte & BAT_STAT_PRESENT) && psp != POWER_SUPPLY_PROP_PRESENT)
|
|
return -ENODEV;
|
|
|
|
switch (psp) {
|
|
case POWER_SUPPLY_PROP_STATUS:
|
|
if (olpc_platform_info.ecver > 0x44) {
|
|
if (ec_byte & BAT_STAT_CHARGING)
|
|
val->intval = POWER_SUPPLY_STATUS_CHARGING;
|
|
else if (ec_byte & BAT_STAT_DISCHARGING)
|
|
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
|
|
else if (ec_byte & BAT_STAT_FULL)
|
|
val->intval = POWER_SUPPLY_STATUS_FULL;
|
|
else /* er,... */
|
|
val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
|
|
} else {
|
|
/* Older EC didn't report charge/discharge bits */
|
|
if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */
|
|
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
|
|
else if (ec_byte & BAT_STAT_FULL)
|
|
val->intval = POWER_SUPPLY_STATUS_FULL;
|
|
else /* Not _necessarily_ true but EC doesn't tell all yet */
|
|
val->intval = POWER_SUPPLY_STATUS_CHARGING;
|
|
break;
|
|
}
|
|
case POWER_SUPPLY_PROP_PRESENT:
|
|
val->intval = !!(ec_byte & BAT_STAT_PRESENT);
|
|
break;
|
|
|
|
case POWER_SUPPLY_PROP_HEALTH:
|
|
if (ec_byte & BAT_STAT_DESTROY)
|
|
val->intval = POWER_SUPPLY_HEALTH_DEAD;
|
|
else {
|
|
ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);
|
|
if (ret)
|
|
return ret;
|
|
|
|
switch (ec_byte) {
|
|
case 0:
|
|
val->intval = POWER_SUPPLY_HEALTH_GOOD;
|
|
break;
|
|
|
|
case BAT_ERR_OVERTEMP:
|
|
val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
|
|
break;
|
|
|
|
case BAT_ERR_OVERVOLTAGE:
|
|
val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
|
|
break;
|
|
|
|
case BAT_ERR_INFOFAIL:
|
|
case BAT_ERR_OUT_OF_CONTROL:
|
|
case BAT_ERR_ID_FAIL:
|
|
case BAT_ERR_ACR_FAIL:
|
|
val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
|
|
break;
|
|
|
|
default:
|
|
/* Eep. We don't know this failure code */
|
|
return -EIO;
|
|
}
|
|
}
|
|
break;
|
|
|
|
case POWER_SUPPLY_PROP_MANUFACTURER:
|
|
ec_byte = BAT_ADDR_MFR_TYPE;
|
|
ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
|
|
if (ret)
|
|
return ret;
|
|
|
|
switch (ec_byte >> 4) {
|
|
case 1:
|
|
val->strval = "Gold Peak";
|
|
break;
|
|
case 2:
|
|
val->strval = "BYD";
|
|
break;
|
|
default:
|
|
val->strval = "Unknown";
|
|
break;
|
|
}
|
|
break;
|
|
case POWER_SUPPLY_PROP_TECHNOLOGY:
|
|
ec_byte = BAT_ADDR_MFR_TYPE;
|
|
ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
|
|
if (ret)
|
|
return ret;
|
|
|
|
switch (ec_byte & 0xf) {
|
|
case 1:
|
|
val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;
|
|
break;
|
|
case 2:
|
|
val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;
|
|
break;
|
|
default:
|
|
val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
|
|
break;
|
|
}
|
|
break;
|
|
case POWER_SUPPLY_PROP_VOLTAGE_AVG:
|
|
ret = olpc_ec_cmd(EC_BAT_VOLTAGE, NULL, 0, (void *)&ec_word, 2);
|
|
if (ret)
|
|
return ret;
|
|
|
|
ec_word = be16_to_cpu(ec_word);
|
|
val->intval = ec_word * 9760L / 32;
|
|
break;
|
|
case POWER_SUPPLY_PROP_CURRENT_AVG:
|
|
ret = olpc_ec_cmd(EC_BAT_CURRENT, NULL, 0, (void *)&ec_word, 2);
|
|
if (ret)
|
|
return ret;
|
|
|
|
ec_word = be16_to_cpu(ec_word);
|
|
val->intval = ec_word * 15625L / 120;
|
|
break;
|
|
case POWER_SUPPLY_PROP_CAPACITY:
|
|
ret = olpc_ec_cmd(EC_BAT_SOC, NULL, 0, &ec_byte, 1);
|
|
if (ret)
|
|
return ret;
|
|
val->intval = ec_byte;
|
|
break;
|
|
case POWER_SUPPLY_PROP_TEMP:
|
|
ret = olpc_ec_cmd(EC_BAT_TEMP, NULL, 0, (void *)&ec_word, 2);
|
|
if (ret)
|
|
return ret;
|
|
ec_word = be16_to_cpu(ec_word);
|
|
val->intval = ec_word * 100 / 256;
|
|
break;
|
|
case POWER_SUPPLY_PROP_TEMP_AMBIENT:
|
|
ret = olpc_ec_cmd(EC_AMB_TEMP, NULL, 0, (void *)&ec_word, 2);
|
|
if (ret)
|
|
return ret;
|
|
|
|
ec_word = be16_to_cpu(ec_word);
|
|
val->intval = ec_word * 100 / 256;
|
|
break;
|
|
case POWER_SUPPLY_PROP_SERIAL_NUMBER:
|
|
ret = olpc_ec_cmd(EC_BAT_SERIAL, NULL, 0, (void *)&ser_buf, 8);
|
|
if (ret)
|
|
return ret;
|
|
|
|
sprintf(bat_serial, "%016llx", (long long)be64_to_cpu(ser_buf));
|
|
val->strval = bat_serial;
|
|
break;
|
|
default:
|
|
ret = -EINVAL;
|
|
break;
|
|
}
|
|
|
|
return ret;
|
|
}
|
|
|
|
static enum power_supply_property olpc_bat_props[] = {
|
|
POWER_SUPPLY_PROP_STATUS,
|
|
POWER_SUPPLY_PROP_PRESENT,
|
|
POWER_SUPPLY_PROP_HEALTH,
|
|
POWER_SUPPLY_PROP_TECHNOLOGY,
|
|
POWER_SUPPLY_PROP_VOLTAGE_AVG,
|
|
POWER_SUPPLY_PROP_CURRENT_AVG,
|
|
POWER_SUPPLY_PROP_CAPACITY,
|
|
POWER_SUPPLY_PROP_TEMP,
|
|
POWER_SUPPLY_PROP_TEMP_AMBIENT,
|
|
POWER_SUPPLY_PROP_MANUFACTURER,
|
|
POWER_SUPPLY_PROP_SERIAL_NUMBER,
|
|
};
|
|
|
|
/*********************************************************************
|
|
* Initialisation
|
|
*********************************************************************/
|
|
|
|
static struct platform_device *bat_pdev;
|
|
|
|
static struct power_supply olpc_bat = {
|
|
.properties = olpc_bat_props,
|
|
.num_properties = ARRAY_SIZE(olpc_bat_props),
|
|
.get_property = olpc_bat_get_property,
|
|
.use_for_apm = 1,
|
|
};
|
|
|
|
void olpc_battery_trigger_uevent(unsigned long cause)
|
|
{
|
|
if (cause & EC_SCI_SRC_ACPWR)
|
|
kobject_uevent(&olpc_ac.dev->kobj, KOBJ_CHANGE);
|
|
if (cause & (EC_SCI_SRC_BATERR|EC_SCI_SRC_BATSOC|EC_SCI_SRC_BATTERY))
|
|
kobject_uevent(&olpc_bat.dev->kobj, KOBJ_CHANGE);
|
|
}
|
|
|
|
static int __init olpc_bat_init(void)
|
|
{
|
|
int ret = 0;
|
|
uint8_t status;
|
|
|
|
if (!olpc_platform_info.ecver)
|
|
return -ENXIO;
|
|
if (olpc_platform_info.ecver < 0x43) {
|
|
printk(KERN_NOTICE "OLPC EC version 0x%02x too old for battery driver.\n", olpc_platform_info.ecver);
|
|
return -ENXIO;
|
|
}
|
|
|
|
ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &status, 1);
|
|
if (ret)
|
|
return ret;
|
|
|
|
/* Ignore the status. It doesn't actually matter */
|
|
|
|
bat_pdev = platform_device_register_simple("olpc-battery", 0, NULL, 0);
|
|
if (IS_ERR(bat_pdev))
|
|
return PTR_ERR(bat_pdev);
|
|
|
|
ret = power_supply_register(&bat_pdev->dev, &olpc_ac);
|
|
if (ret)
|
|
goto ac_failed;
|
|
|
|
olpc_bat.name = bat_pdev->name;
|
|
|
|
ret = power_supply_register(&bat_pdev->dev, &olpc_bat);
|
|
if (ret)
|
|
goto battery_failed;
|
|
|
|
goto success;
|
|
|
|
battery_failed:
|
|
power_supply_unregister(&olpc_ac);
|
|
ac_failed:
|
|
platform_device_unregister(bat_pdev);
|
|
success:
|
|
return ret;
|
|
}
|
|
|
|
static void __exit olpc_bat_exit(void)
|
|
{
|
|
power_supply_unregister(&olpc_bat);
|
|
power_supply_unregister(&olpc_ac);
|
|
platform_device_unregister(bat_pdev);
|
|
}
|
|
|
|
module_init(olpc_bat_init);
|
|
module_exit(olpc_bat_exit);
|
|
|
|
MODULE_AUTHOR("David Woodhouse <dwmw2@infradead.org>");
|
|
MODULE_LICENSE("GPL");
|
|
MODULE_DESCRIPTION("Battery driver for One Laptop Per Child 'XO' machine");
|