mirror of
https://github.com/FEX-Emu/linux.git
synced 2025-01-31 16:13:22 +00:00
8690f47d6e
Without this patch, if the only instructions using r_X are of the BPF_LD | BPF_IND type, r_X would not be reset to 0, using whatever value was there when entering the jited code. With this patch, r_X will be correctly marked as used so it will be reset to 0 in the prologue code. This fix also makes the test "LD_IND byte default X" pass in the test_bpf module when the ARM JIT is enabled. Signed-off-by: Nicolas Schichan <nschichan@freebox.fr> Signed-off-by: David S. Miller <davem@davemloft.net>