Qian Zhang (张谦) reported a potential socket buffer overflow in tipc_msg_build() which is also known as CVE-2016-8632: due to insufficient checks, a buffer overflow can occur if MTU is too short for even tipc headers. As anyone can set device MTU in a user/net namespace, this issue can be abused by a regular user. As agreed in the discussion on Ben Hutchings' original patch, we should check the MTU at the moment a bearer is attached rather than for each processed packet. We also need to repeat the check when bearer MTU is adjusted to new device MTU. UDP case also needs a check to avoid overflow when calculating bearer MTU. Fixes: b97bf3fd8f6a ("[TIPC] Initial merge") Signed-off-by: Michal Kubecek <mkubecek@suse.cz> Reported-by: Qian Zhang (张谦) <zhangqian-c@360.cn> Acked-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: David S. Miller <davem@davemloft.net>