4027789192
It is possible to specify a user offset for the TOD clock, e.g. +2 hours. The TOD clock will carry this offset even if the clock is synchronized with STP. This makes the time stamps acquired with get_sync_clock() useless as another LPAR migth use a different TOD offset. Use the PTFF instrution to get the TOD epoch difference and subtract it from the TOD clock value to get a physical timestamp. As the epoch difference contains the sync check delta as well the LPAR offset value to the physical clock needs to be refreshed after each clock synchronization. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>