Martin Schwidefsky 450e47da67 s390/entry: fix svc number for TIF_SYSCALL system call restart
The load of the svc number in the TIF_SYSCALL restart path needs to be
done with an instruction that loads all 64 bits of %r1, 'lh' only loads
32 bits. If the upper half of %r1 is not zero and has the msb set,
entry64.S will try to execute an svc with a really large number.
What will be in the upper half of %r1 depends on the code generated by
gcc for the functions on the do_signal() callchain.

Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
2012-10-09 14:17:02 +02:00
..
2012-10-04 09:30:33 -07:00
2012-09-26 15:45:29 +02:00
2012-10-09 14:16:58 +02:00
2012-05-05 13:00:25 +02:00