Initial git repository build. I'm not bothering with the full history, even though we have it. We can create a separate "historical" git archive of that later if we want to, and in the meantime it's about 3.2GB when imported into git - space that would just make the early git days unnecessarily complicated, when we don't have a lot of good infrastructure for it. Let it rip!
458 lines
12 KiB
C
458 lines
12 KiB
C
/*
|
|
* linux/drivers/char/8250_pnp.c
|
|
*
|
|
* Probe module for 8250/16550-type ISAPNP serial ports.
|
|
*
|
|
* Based on drivers/char/serial.c, by Linus Torvalds, Theodore Ts'o.
|
|
*
|
|
* Copyright (C) 2001 Russell King, All Rights Reserved.
|
|
*
|
|
* Ported to the Linux PnP Layer - (C) Adam Belay.
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation; either version 2 of the License.
|
|
*
|
|
* $Id: 8250_pnp.c,v 1.10 2002/07/21 21:32:30 rmk Exp $
|
|
*/
|
|
#include <linux/module.h>
|
|
#include <linux/init.h>
|
|
#include <linux/pci.h>
|
|
#include <linux/pnp.h>
|
|
#include <linux/string.h>
|
|
#include <linux/kernel.h>
|
|
#include <linux/serial_core.h>
|
|
#include <linux/bitops.h>
|
|
|
|
#include <asm/byteorder.h>
|
|
|
|
#include "8250.h"
|
|
|
|
#define UNKNOWN_DEV 0x3000
|
|
|
|
|
|
static const struct pnp_device_id pnp_dev_table[] = {
|
|
/* Archtek America Corp. */
|
|
/* Archtek SmartLink Modem 3334BT Plug & Play */
|
|
{ "AAC000F", 0 },
|
|
/* Anchor Datacomm BV */
|
|
/* SXPro 144 External Data Fax Modem Plug & Play */
|
|
{ "ADC0001", 0 },
|
|
/* SXPro 288 External Data Fax Modem Plug & Play */
|
|
{ "ADC0002", 0 },
|
|
/* PROLiNK 1456VH ISA PnP K56flex Fax Modem */
|
|
{ "AEI0250", 0 },
|
|
/* Actiontec ISA PNP 56K X2 Fax Modem */
|
|
{ "AEI1240", 0 },
|
|
/* Rockwell 56K ACF II Fax+Data+Voice Modem */
|
|
{ "AKY1021", 0 /*SPCI_FL_NO_SHIRQ*/ },
|
|
/* AZT3005 PnP SOUND DEVICE */
|
|
{ "AZT4001", 0 },
|
|
/* Best Data Products Inc. Smart One 336F PnP Modem */
|
|
{ "BDP3336", 0 },
|
|
/* Boca Research */
|
|
/* Boca Complete Ofc Communicator 14.4 Data-FAX */
|
|
{ "BRI0A49", 0 },
|
|
/* Boca Research 33,600 ACF Modem */
|
|
{ "BRI1400", 0 },
|
|
/* Boca 33.6 Kbps Internal FD34FSVD */
|
|
{ "BRI3400", 0 },
|
|
/* Boca 33.6 Kbps Internal FD34FSVD */
|
|
{ "BRI0A49", 0 },
|
|
/* Best Data Products Inc. Smart One 336F PnP Modem */
|
|
{ "BDP3336", 0 },
|
|
/* Computer Peripherals Inc */
|
|
/* EuroViVa CommCenter-33.6 SP PnP */
|
|
{ "CPI4050", 0 },
|
|
/* Creative Labs */
|
|
/* Creative Labs Phone Blaster 28.8 DSVD PnP Voice */
|
|
{ "CTL3001", 0 },
|
|
/* Creative Labs Modem Blaster 28.8 DSVD PnP Voice */
|
|
{ "CTL3011", 0 },
|
|
/* Creative */
|
|
/* Creative Modem Blaster Flash56 DI5601-1 */
|
|
{ "DMB1032", 0 },
|
|
/* Creative Modem Blaster V.90 DI5660 */
|
|
{ "DMB2001", 0 },
|
|
/* E-Tech */
|
|
/* E-Tech CyberBULLET PC56RVP */
|
|
{ "ETT0002", 0 },
|
|
/* FUJITSU */
|
|
/* Fujitsu 33600 PnP-I2 R Plug & Play */
|
|
{ "FUJ0202", 0 },
|
|
/* Fujitsu FMV-FX431 Plug & Play */
|
|
{ "FUJ0205", 0 },
|
|
/* Fujitsu 33600 PnP-I4 R Plug & Play */
|
|
{ "FUJ0206", 0 },
|
|
/* Fujitsu Fax Voice 33600 PNP-I5 R Plug & Play */
|
|
{ "FUJ0209", 0 },
|
|
/* Archtek America Corp. */
|
|
/* Archtek SmartLink Modem 3334BT Plug & Play */
|
|
{ "GVC000F", 0 },
|
|
/* Hayes */
|
|
/* Hayes Optima 288 V.34-V.FC + FAX + Voice Plug & Play */
|
|
{ "HAY0001", 0 },
|
|
/* Hayes Optima 336 V.34 + FAX + Voice PnP */
|
|
{ "HAY000C", 0 },
|
|
/* Hayes Optima 336B V.34 + FAX + Voice PnP */
|
|
{ "HAY000D", 0 },
|
|
/* Hayes Accura 56K Ext Fax Modem PnP */
|
|
{ "HAY5670", 0 },
|
|
/* Hayes Accura 56K Ext Fax Modem PnP */
|
|
{ "HAY5674", 0 },
|
|
/* Hayes Accura 56K Fax Modem PnP */
|
|
{ "HAY5675", 0 },
|
|
/* Hayes 288, V.34 + FAX */
|
|
{ "HAYF000", 0 },
|
|
/* Hayes Optima 288 V.34 + FAX + Voice, Plug & Play */
|
|
{ "HAYF001", 0 },
|
|
/* IBM */
|
|
/* IBM Thinkpad 701 Internal Modem Voice */
|
|
{ "IBM0033", 0 },
|
|
/* Intertex */
|
|
/* Intertex 28k8 33k6 Voice EXT PnP */
|
|
{ "IXDC801", 0 },
|
|
/* Intertex 33k6 56k Voice EXT PnP */
|
|
{ "IXDC901", 0 },
|
|
/* Intertex 28k8 33k6 Voice SP EXT PnP */
|
|
{ "IXDD801", 0 },
|
|
/* Intertex 33k6 56k Voice SP EXT PnP */
|
|
{ "IXDD901", 0 },
|
|
/* Intertex 28k8 33k6 Voice SP INT PnP */
|
|
{ "IXDF401", 0 },
|
|
/* Intertex 28k8 33k6 Voice SP EXT PnP */
|
|
{ "IXDF801", 0 },
|
|
/* Intertex 33k6 56k Voice SP EXT PnP */
|
|
{ "IXDF901", 0 },
|
|
/* Kortex International */
|
|
/* KORTEX 28800 Externe PnP */
|
|
{ "KOR4522", 0 },
|
|
/* KXPro 33.6 Vocal ASVD PnP */
|
|
{ "KORF661", 0 },
|
|
/* Lasat */
|
|
/* LASAT Internet 33600 PnP */
|
|
{ "LAS4040", 0 },
|
|
/* Lasat Safire 560 PnP */
|
|
{ "LAS4540", 0 },
|
|
/* Lasat Safire 336 PnP */
|
|
{ "LAS5440", 0 },
|
|
/* Microcom, Inc. */
|
|
/* Microcom TravelPorte FAST V.34 Plug & Play */
|
|
{ "MNP0281", 0 },
|
|
/* Microcom DeskPorte V.34 FAST or FAST+ Plug & Play */
|
|
{ "MNP0336", 0 },
|
|
/* Microcom DeskPorte FAST EP 28.8 Plug & Play */
|
|
{ "MNP0339", 0 },
|
|
/* Microcom DeskPorte 28.8P Plug & Play */
|
|
{ "MNP0342", 0 },
|
|
/* Microcom DeskPorte FAST ES 28.8 Plug & Play */
|
|
{ "MNP0500", 0 },
|
|
/* Microcom DeskPorte FAST ES 28.8 Plug & Play */
|
|
{ "MNP0501", 0 },
|
|
/* Microcom DeskPorte 28.8S Internal Plug & Play */
|
|
{ "MNP0502", 0 },
|
|
/* Motorola */
|
|
/* Motorola BitSURFR Plug & Play */
|
|
{ "MOT1105", 0 },
|
|
/* Motorola TA210 Plug & Play */
|
|
{ "MOT1111", 0 },
|
|
/* Motorola HMTA 200 (ISDN) Plug & Play */
|
|
{ "MOT1114", 0 },
|
|
/* Motorola BitSURFR Plug & Play */
|
|
{ "MOT1115", 0 },
|
|
/* Motorola Lifestyle 28.8 Internal */
|
|
{ "MOT1190", 0 },
|
|
/* Motorola V.3400 Plug & Play */
|
|
{ "MOT1501", 0 },
|
|
/* Motorola Lifestyle 28.8 V.34 Plug & Play */
|
|
{ "MOT1502", 0 },
|
|
/* Motorola Power 28.8 V.34 Plug & Play */
|
|
{ "MOT1505", 0 },
|
|
/* Motorola ModemSURFR External 28.8 Plug & Play */
|
|
{ "MOT1509", 0 },
|
|
/* Motorola Premier 33.6 Desktop Plug & Play */
|
|
{ "MOT150A", 0 },
|
|
/* Motorola VoiceSURFR 56K External PnP */
|
|
{ "MOT150F", 0 },
|
|
/* Motorola ModemSURFR 56K External PnP */
|
|
{ "MOT1510", 0 },
|
|
/* Motorola ModemSURFR 56K Internal PnP */
|
|
{ "MOT1550", 0 },
|
|
/* Motorola ModemSURFR Internal 28.8 Plug & Play */
|
|
{ "MOT1560", 0 },
|
|
/* Motorola Premier 33.6 Internal Plug & Play */
|
|
{ "MOT1580", 0 },
|
|
/* Motorola OnlineSURFR 28.8 Internal Plug & Play */
|
|
{ "MOT15B0", 0 },
|
|
/* Motorola VoiceSURFR 56K Internal PnP */
|
|
{ "MOT15F0", 0 },
|
|
/* Com 1 */
|
|
/* Deskline K56 Phone System PnP */
|
|
{ "MVX00A1", 0 },
|
|
/* PC Rider K56 Phone System PnP */
|
|
{ "MVX00F2", 0 },
|
|
/* NEC 98NOTE SPEAKER PHONE FAX MODEM(33600bps) */
|
|
{ "nEC8241", 0 },
|
|
/* Pace 56 Voice Internal Plug & Play Modem */
|
|
{ "PMC2430", 0 },
|
|
/* Generic */
|
|
/* Generic standard PC COM port */
|
|
{ "PNP0500", 0 },
|
|
/* Generic 16550A-compatible COM port */
|
|
{ "PNP0501", 0 },
|
|
/* Compaq 14400 Modem */
|
|
{ "PNPC000", 0 },
|
|
/* Compaq 2400/9600 Modem */
|
|
{ "PNPC001", 0 },
|
|
/* Dial-Up Networking Serial Cable between 2 PCs */
|
|
{ "PNPC031", 0 },
|
|
/* Dial-Up Networking Parallel Cable between 2 PCs */
|
|
{ "PNPC032", 0 },
|
|
/* Standard 9600 bps Modem */
|
|
{ "PNPC100", 0 },
|
|
/* Standard 14400 bps Modem */
|
|
{ "PNPC101", 0 },
|
|
/* Standard 28800 bps Modem*/
|
|
{ "PNPC102", 0 },
|
|
/* Standard Modem*/
|
|
{ "PNPC103", 0 },
|
|
/* Standard 9600 bps Modem*/
|
|
{ "PNPC104", 0 },
|
|
/* Standard 14400 bps Modem*/
|
|
{ "PNPC105", 0 },
|
|
/* Standard 28800 bps Modem*/
|
|
{ "PNPC106", 0 },
|
|
/* Standard Modem */
|
|
{ "PNPC107", 0 },
|
|
/* Standard 9600 bps Modem */
|
|
{ "PNPC108", 0 },
|
|
/* Standard 14400 bps Modem */
|
|
{ "PNPC109", 0 },
|
|
/* Standard 28800 bps Modem */
|
|
{ "PNPC10A", 0 },
|
|
/* Standard Modem */
|
|
{ "PNPC10B", 0 },
|
|
/* Standard 9600 bps Modem */
|
|
{ "PNPC10C", 0 },
|
|
/* Standard 14400 bps Modem */
|
|
{ "PNPC10D", 0 },
|
|
/* Standard 28800 bps Modem */
|
|
{ "PNPC10E", 0 },
|
|
/* Standard Modem */
|
|
{ "PNPC10F", 0 },
|
|
/* Standard PCMCIA Card Modem */
|
|
{ "PNP2000", 0 },
|
|
/* Rockwell */
|
|
/* Modular Technology */
|
|
/* Rockwell 33.6 DPF Internal PnP */
|
|
/* Modular Technology 33.6 Internal PnP */
|
|
{ "ROK0030", 0 },
|
|
/* Kortex International */
|
|
/* KORTEX 14400 Externe PnP */
|
|
{ "ROK0100", 0 },
|
|
/* Rockwell 28.8 */
|
|
{ "ROK4120", 0 },
|
|
/* Viking Components, Inc */
|
|
/* Viking 28.8 INTERNAL Fax+Data+Voice PnP */
|
|
{ "ROK4920", 0 },
|
|
/* Rockwell */
|
|
/* British Telecom */
|
|
/* Modular Technology */
|
|
/* Rockwell 33.6 DPF External PnP */
|
|
/* BT Prologue 33.6 External PnP */
|
|
/* Modular Technology 33.6 External PnP */
|
|
{ "RSS00A0", 0 },
|
|
/* Viking 56K FAX INT */
|
|
{ "RSS0262", 0 },
|
|
/* K56 par,VV,Voice,Speakphone,AudioSpan,PnP */
|
|
{ "RSS0250", 0 },
|
|
/* SupraExpress 28.8 Data/Fax PnP modem */
|
|
{ "SUP1310", 0 },
|
|
/* SupraExpress 33.6 Data/Fax PnP modem */
|
|
{ "SUP1421", 0 },
|
|
/* SupraExpress 33.6 Data/Fax PnP modem */
|
|
{ "SUP1590", 0 },
|
|
/* SupraExpress 33.6 Data/Fax PnP modem */
|
|
{ "SUP1760", 0 },
|
|
/* Phoebe Micro */
|
|
/* Phoebe Micro 33.6 Data Fax 1433VQH Plug & Play */
|
|
{ "TEX0011", 0 },
|
|
/* Archtek America Corp. */
|
|
/* Archtek SmartLink Modem 3334BT Plug & Play */
|
|
{ "UAC000F", 0 },
|
|
/* 3Com Corp. */
|
|
/* Gateway Telepath IIvi 33.6 */
|
|
{ "USR0000", 0 },
|
|
/* U.S. Robotics Sporster 33.6K Fax INT PnP */
|
|
{ "USR0002", 0 },
|
|
/* Sportster Vi 14.4 PnP FAX Voicemail */
|
|
{ "USR0004", 0 },
|
|
/* U.S. Robotics 33.6K Voice INT PnP */
|
|
{ "USR0006", 0 },
|
|
/* U.S. Robotics 33.6K Voice EXT PnP */
|
|
{ "USR0007", 0 },
|
|
/* U.S. Robotics Courier V.Everything INT PnP */
|
|
{ "USR0009", 0 },
|
|
/* U.S. Robotics 33.6K Voice INT PnP */
|
|
{ "USR2002", 0 },
|
|
/* U.S. Robotics 56K Voice INT PnP */
|
|
{ "USR2070", 0 },
|
|
/* U.S. Robotics 56K Voice EXT PnP */
|
|
{ "USR2080", 0 },
|
|
/* U.S. Robotics 56K FAX INT */
|
|
{ "USR3031", 0 },
|
|
/* U.S. Robotics 56K FAX INT */
|
|
{ "USR3050", 0 },
|
|
/* U.S. Robotics 56K Voice INT PnP */
|
|
{ "USR3070", 0 },
|
|
/* U.S. Robotics 56K Voice EXT PnP */
|
|
{ "USR3080", 0 },
|
|
/* U.S. Robotics 56K Voice INT PnP */
|
|
{ "USR3090", 0 },
|
|
/* U.S. Robotics 56K Message */
|
|
{ "USR9100", 0 },
|
|
/* U.S. Robotics 56K FAX EXT PnP*/
|
|
{ "USR9160", 0 },
|
|
/* U.S. Robotics 56K FAX INT PnP*/
|
|
{ "USR9170", 0 },
|
|
/* U.S. Robotics 56K Voice EXT PnP*/
|
|
{ "USR9180", 0 },
|
|
/* U.S. Robotics 56K Voice INT PnP*/
|
|
{ "USR9190", 0 },
|
|
/* Rockwell's (PORALiNK) 33600 INT PNP */
|
|
{ "WCI0003", 0 },
|
|
/* Unkown PnP modems */
|
|
{ "PNPCXXX", UNKNOWN_DEV },
|
|
/* More unkown PnP modems */
|
|
{ "PNPDXXX", UNKNOWN_DEV },
|
|
{ "", 0 }
|
|
};
|
|
|
|
MODULE_DEVICE_TABLE(pnp, pnp_dev_table);
|
|
|
|
static char *modem_names[] __devinitdata = {
|
|
"MODEM", "Modem", "modem", "FAX", "Fax", "fax",
|
|
"56K", "56k", "K56", "33.6", "28.8", "14.4",
|
|
"33,600", "28,800", "14,400", "33.600", "28.800", "14.400",
|
|
"33600", "28800", "14400", "V.90", "V.34", "V.32", NULL
|
|
};
|
|
|
|
static int __devinit check_name(char *name)
|
|
{
|
|
char **tmp;
|
|
|
|
for (tmp = modem_names; *tmp; tmp++)
|
|
if (strstr(name, *tmp))
|
|
return 1;
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int __devinit check_resources(struct pnp_option *option)
|
|
{
|
|
struct pnp_option *tmp;
|
|
if (!option)
|
|
return 0;
|
|
|
|
for (tmp = option; tmp; tmp = tmp->next) {
|
|
struct pnp_port *port;
|
|
for (port = tmp->port; port; port = port->next)
|
|
if ((port->size == 8) &&
|
|
((port->min == 0x2f8) ||
|
|
(port->min == 0x3f8) ||
|
|
(port->min == 0x2e8) ||
|
|
(port->min == 0x3e8)))
|
|
return 1;
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* Given a complete unknown PnP device, try to use some heuristics to
|
|
* detect modems. Currently use such heuristic set:
|
|
* - dev->name or dev->bus->name must contain "modem" substring;
|
|
* - device must have only one IO region (8 byte long) with base address
|
|
* 0x2e8, 0x3e8, 0x2f8 or 0x3f8.
|
|
*
|
|
* Such detection looks very ugly, but can detect at least some of numerous
|
|
* PnP modems, alternatively we must hardcode all modems in pnp_devices[]
|
|
* table.
|
|
*/
|
|
static int __devinit serial_pnp_guess_board(struct pnp_dev *dev, int *flags)
|
|
{
|
|
if (!(check_name(pnp_dev_name(dev)) || (dev->card && check_name(dev->card->name))))
|
|
return -ENODEV;
|
|
|
|
if (check_resources(dev->independent))
|
|
return 0;
|
|
|
|
if (check_resources(dev->dependent))
|
|
return 0;
|
|
|
|
return -ENODEV;
|
|
}
|
|
|
|
static int __devinit
|
|
serial_pnp_probe(struct pnp_dev * dev, const struct pnp_device_id *dev_id)
|
|
{
|
|
struct uart_port port;
|
|
int ret, line, flags = dev_id->driver_data;
|
|
|
|
if (flags & UNKNOWN_DEV) {
|
|
ret = serial_pnp_guess_board(dev, &flags);
|
|
if (ret < 0)
|
|
return ret;
|
|
}
|
|
|
|
memset(&port, 0, sizeof(struct uart_port));
|
|
port.irq = pnp_irq(dev,0);
|
|
port.iobase = pnp_port_start(dev, 0);
|
|
|
|
#ifdef SERIAL_DEBUG_PNP
|
|
printk("Setup PNP port: port %x, irq %d, type %d\n",
|
|
port.iobase, port.irq, port.iotype);
|
|
#endif
|
|
|
|
port.flags = UPF_SKIP_TEST | UPF_BOOT_AUTOCONF;
|
|
port.uartclk = 1843200;
|
|
port.dev = &dev->dev;
|
|
|
|
line = serial8250_register_port(&port);
|
|
|
|
if (line >= 0)
|
|
pnp_set_drvdata(dev, (void *)((long)line + 1));
|
|
return line >= 0 ? 0 : -ENODEV;
|
|
|
|
}
|
|
|
|
static void __devexit serial_pnp_remove(struct pnp_dev * dev)
|
|
{
|
|
long line = (long)pnp_get_drvdata(dev);
|
|
if (line)
|
|
serial8250_unregister_port(line - 1);
|
|
}
|
|
|
|
static struct pnp_driver serial_pnp_driver = {
|
|
.name = "serial",
|
|
.id_table = pnp_dev_table,
|
|
.probe = serial_pnp_probe,
|
|
.remove = __devexit_p(serial_pnp_remove),
|
|
};
|
|
|
|
static int __init serial8250_pnp_init(void)
|
|
{
|
|
return pnp_register_driver(&serial_pnp_driver);
|
|
}
|
|
|
|
static void __exit serial8250_pnp_exit(void)
|
|
{
|
|
pnp_unregister_driver(&serial_pnp_driver);
|
|
}
|
|
|
|
module_init(serial8250_pnp_init);
|
|
module_exit(serial8250_pnp_exit);
|
|
|
|