Commit ef923214 ("perf_counter: powerpc: use u64 for event
codes internally") introduced a bug where the return value from
function find_alternative_bdecode gets put into a u64 variable
and later tested to see if it is < 0. The effect is that we
get extra, bogus event code alternatives on POWER5 and POWER5+,
leading to error messages such as "oops compute_mmcr failed"
being printed and counters not counting properly.
This fixes it by using s64 for the return type of
find_alternative_bdecode and for the local variable that the
caller puts the value in. It also makes the event argument a
u64 on POWER5+ for consistency.
Signed-off-by: Paul Mackerras <paulus@samba.org>
Cc: Peter Zijlstra <a.p.zijlstra@chello.nl>
Cc: Mike Galbraith <efault@gmx.de>
Cc: Paul Mackerras <paulus@samba.org>
Cc: Corey Ashford <cjashfor@linux.vnet.ibm.com>
Cc: Marcelo Tosatti <mtosatti@redhat.com>
Cc: Arnaldo Carvalho de Melo <acme@redhat.com>
Cc: Thomas Gleixner <tglx@linutronix.de>
Cc: John Kacur <jkacur@redhat.com>
Cc: Stephane Eranian <eranian@googlemail.com>
LKML-Reference: <18982.17586.666132.90983@cargo.ozlabs.ibm.com>
Signed-off-by: Ingo Molnar <mingo@elte.hu>