Guenter Roeck 8c958c703e hwmon: (pmbus/ltc2978) Fix temperature reporting
On LTC2978, only READ_TEMPERATURE is supported. It reports
the internal junction temperature. This register is unpaged.

On LTC3880, READ_TEMPERATURE and READ_TEMPERATURE2 are supported.
READ_TEMPERATURE is paged and reports external temperatures.
READ_TEMPERATURE2 is unpaged and reports the internal junction
temperature.

Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Cc: stable@vger.kernel.org # 3.2+
Acked-by: Jean Delvare <khali@linux-fr.org>
2013-03-14 09:03:51 -07:00
..