pca954x power-on default is channel 0 connected. If multiple pca954x muxes are connected to the same physical I2C bus, the parent bus will see channel 0 devices behind both muxes by default. This is bad. Scenario: -- pca954x @ 0x70 -- ch 0 (I2C-bus-101) -- EEPROM @ 0x50 | I2C-bus-1 --- | -- pca954x @ 0x71 -- ch 0 (I2C-bus-111) -- EEPROM @ 0x50 1. Load I2C bus driver: creates I2C-bus-1 2. Load pca954x driver: creates virtual I2C-bus-101 and I2C-bus-111 3. Load eeprom driver 4. Try to read EEPROM @ 0x50 on I2C-bus-101. The transaction will also bleed onto I2C-bus-111 because pca954x @ 0x71 channel 0 is connected by default. Fix: Initialize pca954x to disconnected state in pca954x_probe() Signed-off-by: Petri Gynther <pgynther@google.com> Signed-off-by: Jean Delvare <khali@linux-fr.org> Cc: stable@kernel.org |
||
---|---|---|
.. | ||