mirror of
https://github.com/FEX-Emu/linux.git
synced 2024-12-27 11:55:53 +00:00
ed4f20943c
Converting a 64 Bit TOD format value to nanoseconds means that the value must be divided by 4.096. In order to achieve that we multiply with 125 and divide by 512. When used within sched_clock() this triggers an overflow after appr. 417 days. Resulting in a sched_clock() return value that is much smaller than previously and therefore may cause all sort of weird things in subsystems that rely on a monotonic sched_clock() behaviour. To fix this implement a tod_to_ns() helper function which converts TOD values without overflow and call this function from both places that open coded the conversion: sched_clock() and kvm_s390_handle_wait(). Cc: stable@kernel.org Reviewed-by: Martin Schwidefsky <schwidefsky@de.ibm.com> Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com> |
||
---|---|---|
.. | ||
asm | ||
uapi/asm |