Martin Hicks a34b6fc04d [PATCH] libata: PHY reset requires writing 0x4 to SControl
Hi,

Reading the Intel VSC and AHCI it seems like writing 0x302 is incorrect.
The only valid values are 4, 1 and 0.  Writing 4 disables the
PHY.

Signed-off-by: Martin Hicks <mort@bork.org>
Signed-off-by: Jeff Garzik <jeff@garzik.org>
2006-08-10 08:29:12 -04:00
..
2006-07-03 09:41:12 -05:00
2006-07-03 09:41:12 -05:00
2006-07-03 09:41:12 -05:00
2006-07-03 09:41:12 -05:00
2006-07-03 09:41:12 -05:00
2006-07-03 09:41:12 -05:00
2006-06-30 19:25:36 +02:00
2006-07-24 22:47:14 -07:00
2006-04-13 10:13:30 -05:00
2006-05-20 09:35:20 -05:00
2006-06-25 10:00:58 -07:00
2006-06-25 10:00:58 -07:00
2006-06-26 09:58:18 -07:00
2006-07-03 09:41:12 -05:00
2006-07-03 09:41:12 -05:00
2006-06-26 09:30:00 -05:00
2006-07-03 09:41:12 -05:00
2006-07-03 09:41:12 -05:00
2006-07-09 11:27:03 -05:00
2006-06-29 11:06:30 -04:00