Tuomas Tynkkynen 89ac8567b9 clk: tegra30: Don't wait for PLL_U lock bit
The lock bit on PLL_U does not seem to be working correctly and
sometimes never gets set when waiting for the PLL to come up.
Remove the TEGRA_PLL_USE_LOCK flag to use a constant delay.

Signed-off-by: Tuomas Tynkkynen <ttynkkynen@nvidia.com>
Tested-by: Stephen Warren <swarren@nvidia.com>
Acked-by: Stephen Warren <swarren@nvidia.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
2013-08-28 19:08:09 -07:00
..