The I2C specification explicitly describes both SDA and SCL as bidirectional lines. An I2C master with a read-only SCL is thus not compliant. If a slow slave stretches the clock, errors will happen, so the bus can't be considered as reliable. Signed-off-by: Jean Delvare <khali@linux-fr.org>