NeilBrown bf2cb0dab8 md: Fix removal of extra drives when converting RAID6 to RAID5
When a RAID6 is converted to a RAID5, the extra drive should
be discarded.  However it isn't due to a typo in a comparison.

This bug was introduced in commit e93f68a1fc6 in 2.6.35-rc4
and is suitable for any -stable since than.

As the extra drive is not removed, the 'degraded' counter is wrong and
so the RAID5 will not respond correctly to a subsequent failure.

Cc: stable@kernel.org
Signed-off-by: NeilBrown <neilb@suse.de>
2011-01-14 09:14:34 +11:00
..
2010-08-12 04:14:13 +01:00
2010-08-12 04:14:11 +01:00
2010-08-12 04:14:32 +01:00
2007-10-20 02:01:26 +01:00
2010-08-12 04:14:12 +01:00
2010-08-12 04:14:08 +01:00
2010-09-10 12:35:38 +02:00
2011-01-14 09:14:34 +11:00
2010-09-10 12:35:38 +02:00
2010-09-10 12:35:38 +02:00
2011-01-14 09:14:33 +11:00
2010-10-29 16:40:33 +11:00
2010-09-10 12:35:38 +02:00
2011-01-14 09:14:33 +11:00