Current implementation for ti-sysc powers down the module once module init is complete. However, right after power is disabled, it is enabled via runtime PM. This is unnecessary so avoid it by re-ordering the events a bit; move powering down of the module post runtime PM enable which makes sure the use counts are maintained properly and there is no extra power down/up sequence for the module. Signed-off-by: Tero Kristo <t-kristo@ti.com> Signed-off-by: Tony Lindgren <tony@atomide.com> |
||
---|---|---|
.. | ||