mirror of
https://github.com/FEX-Emu/linux.git
synced 2025-02-02 09:05:51 +00:00
d91e16943f
DS1339 manual, page 6, chapter Date and time operation: The DS1339 can be run in either 12-hour or 24-hour mode. Bit 6 of the hours register is defined as the 12-hour or 24-hour mode-select bit. When high, the 12-hour mode is selected. Patch below makes ds1337 driver work as documented in manual. Signed-off-by: Ladislav Michl <ladis@linux-mips.org> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de> Signed-off-by: Linus Torvalds <torvalds@osdl.org>