mirror of
https://github.com/FEX-Emu/linux.git
synced 2024-12-22 09:22:37 +00:00
ede7fbdf52
Part 3: Move the drivers documentation, plus two general documentation files. Note that the patch "adds trailing whitespace", because it does move the files as-is, and some files happen to have trailing whitespace. Signed-off-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
122 lines
4.4 KiB
Plaintext
122 lines
4.4 KiB
Plaintext
Kernel driver lm90
|
|
==================
|
|
|
|
Supported chips:
|
|
* National Semiconductor LM90
|
|
Prefix: 'lm90'
|
|
Addresses scanned: I2C 0x4c
|
|
Datasheet: Publicly available at the National Semiconductor website
|
|
http://www.national.com/pf/LM/LM90.html
|
|
* National Semiconductor LM89
|
|
Prefix: 'lm99'
|
|
Addresses scanned: I2C 0x4c and 0x4d
|
|
Datasheet: Publicly available at the National Semiconductor website
|
|
http://www.national.com/pf/LM/LM89.html
|
|
* National Semiconductor LM99
|
|
Prefix: 'lm99'
|
|
Addresses scanned: I2C 0x4c and 0x4d
|
|
Datasheet: Publicly available at the National Semiconductor website
|
|
http://www.national.com/pf/LM/LM99.html
|
|
* National Semiconductor LM86
|
|
Prefix: 'lm86'
|
|
Addresses scanned: I2C 0x4c
|
|
Datasheet: Publicly available at the National Semiconductor website
|
|
http://www.national.com/pf/LM/LM86.html
|
|
* Analog Devices ADM1032
|
|
Prefix: 'adm1032'
|
|
Addresses scanned: I2C 0x4c
|
|
Datasheet: Publicly available at the Analog Devices website
|
|
http://products.analog.com/products/info.asp?product=ADM1032
|
|
* Analog Devices ADT7461
|
|
Prefix: 'adt7461'
|
|
Addresses scanned: I2C 0x4c
|
|
Datasheet: Publicly available at the Analog Devices website
|
|
http://products.analog.com/products/info.asp?product=ADT7461
|
|
Note: Only if in ADM1032 compatibility mode
|
|
* Maxim MAX6657
|
|
Prefix: 'max6657'
|
|
Addresses scanned: I2C 0x4c
|
|
Datasheet: Publicly available at the Maxim website
|
|
http://www.maxim-ic.com/quick_view2.cfm/qv_pk/2578
|
|
* Maxim MAX6658
|
|
Prefix: 'max6657'
|
|
Addresses scanned: I2C 0x4c
|
|
Datasheet: Publicly available at the Maxim website
|
|
http://www.maxim-ic.com/quick_view2.cfm/qv_pk/2578
|
|
* Maxim MAX6659
|
|
Prefix: 'max6657'
|
|
Addresses scanned: I2C 0x4c, 0x4d (unsupported 0x4e)
|
|
Datasheet: Publicly available at the Maxim website
|
|
http://www.maxim-ic.com/quick_view2.cfm/qv_pk/2578
|
|
|
|
|
|
Author: Jean Delvare <khali@linux-fr.org>
|
|
|
|
|
|
Description
|
|
-----------
|
|
|
|
The LM90 is a digital temperature sensor. It senses its own temperature as
|
|
well as the temperature of up to one external diode. It is compatible
|
|
with many other devices such as the LM86, the LM89, the LM99, the ADM1032,
|
|
the MAX6657, MAX6658 and the MAX6659 all of which are supported by this driver.
|
|
Note that there is no easy way to differentiate between the last three
|
|
variants. The extra address and features of the MAX6659 are not supported by
|
|
this driver. Additionally, the ADT7461 is supported if found in ADM1032
|
|
compatibility mode.
|
|
|
|
The specificity of this family of chipsets over the ADM1021/LM84
|
|
family is that it features critical limits with hysteresis, and an
|
|
increased resolution of the remote temperature measurement.
|
|
|
|
The different chipsets of the family are not strictly identical, although
|
|
very similar. This driver doesn't handle any specific feature for now,
|
|
but could if there ever was a need for it. For reference, here comes a
|
|
non-exhaustive list of specific features:
|
|
|
|
LM90:
|
|
* Filter and alert configuration register at 0xBF.
|
|
* ALERT is triggered by temperatures over critical limits.
|
|
|
|
LM86 and LM89:
|
|
* Same as LM90
|
|
* Better external channel accuracy
|
|
|
|
LM99:
|
|
* Same as LM89
|
|
* External temperature shifted by 16 degrees down
|
|
|
|
ADM1032:
|
|
* Consecutive alert register at 0x22.
|
|
* Conversion averaging.
|
|
* Up to 64 conversions/s.
|
|
* ALERT is triggered by open remote sensor.
|
|
|
|
ADT7461
|
|
* Extended temperature range (breaks compatibility)
|
|
* Lower resolution for remote temperature
|
|
|
|
MAX6657 and MAX6658:
|
|
* Remote sensor type selection
|
|
|
|
MAX6659
|
|
* Selectable address
|
|
* Second critical temperature limit
|
|
* Remote sensor type selection
|
|
|
|
All temperature values are given in degrees Celsius. Resolution
|
|
is 1.0 degree for the local temperature, 0.125 degree for the remote
|
|
temperature.
|
|
|
|
Each sensor has its own high and low limits, plus a critical limit.
|
|
Additionally, there is a relative hysteresis value common to both critical
|
|
values. To make life easier to user-space applications, two absolute values
|
|
are exported, one for each channel, but these values are of course linked.
|
|
Only the local hysteresis can be set from user-space, and the same delta
|
|
applies to the remote hysteresis.
|
|
|
|
The lm90 driver will not update its values more frequently than every
|
|
other second; reading them more often will do no harm, but will return
|
|
'old' values.
|
|
|