mirror of
https://github.com/joel16/android_kernel_sony_msm8994_rework.git
synced 2025-01-01 09:08:55 +00:00
e100: update e100.txt
Signed-off-by: Jesse Brandeburg <jesse.brandeburg@intel.com>
This commit is contained in:
parent
add1878439
commit
823f8dd177
@ -1,16 +1,17 @@
|
|||||||
Linux* Base Driver for the Intel(R) PRO/100 Family of Adapters
|
Linux* Base Driver for the Intel(R) PRO/100 Family of Adapters
|
||||||
==============================================================
|
==============================================================
|
||||||
|
|
||||||
November 17, 2004
|
November 15, 2005
|
||||||
|
|
||||||
|
|
||||||
Contents
|
Contents
|
||||||
========
|
========
|
||||||
|
|
||||||
- In This Release
|
- In This Release
|
||||||
- Identifying Your Adapter
|
- Identifying Your Adapter
|
||||||
|
- Building and Installation
|
||||||
- Driver Configuration Parameters
|
- Driver Configuration Parameters
|
||||||
- Additional Configurations
|
- Additional Configurations
|
||||||
|
- Known Issues
|
||||||
- Support
|
- Support
|
||||||
|
|
||||||
|
|
||||||
@ -18,18 +19,30 @@ In This Release
|
|||||||
===============
|
===============
|
||||||
|
|
||||||
This file describes the Linux* Base Driver for the Intel(R) PRO/100 Family of
|
This file describes the Linux* Base Driver for the Intel(R) PRO/100 Family of
|
||||||
Adapters, version 3.3.x. This driver supports 2.4.x and 2.6.x kernels.
|
Adapters. This driver includes support for Itanium(R)2-based systems.
|
||||||
|
|
||||||
|
For questions related to hardware requirements, refer to the documentation
|
||||||
|
supplied with your Intel PRO/100 adapter.
|
||||||
|
|
||||||
|
The following features are now available in supported kernels:
|
||||||
|
- Native VLANs
|
||||||
|
- Channel Bonding (teaming)
|
||||||
|
- SNMP
|
||||||
|
|
||||||
|
Channel Bonding documentation can be found in the Linux kernel source:
|
||||||
|
/Documentation/networking/bonding.txt
|
||||||
|
|
||||||
|
|
||||||
Identifying Your Adapter
|
Identifying Your Adapter
|
||||||
========================
|
========================
|
||||||
|
|
||||||
For more information on how to identify your adapter, go to the Adapter &
|
For more information on how to identify your adapter, go to the Adapter &
|
||||||
Driver ID Guide at:
|
Driver ID Guide at:
|
||||||
|
|
||||||
http://support.intel.com/support/network/adapter/pro100/21397.htm
|
http://support.intel.com/support/network/adapter/pro100/21397.htm
|
||||||
|
|
||||||
For the latest Intel network drivers for Linux, refer to the following
|
For the latest Intel network drivers for Linux, refer to the following
|
||||||
website. In the search field, enter your adapter name or type, or use the
|
website. In the search field, enter your adapter name or type, or use the
|
||||||
networking link on the left to search for your adapter:
|
networking link on the left to search for your adapter:
|
||||||
|
|
||||||
http://downloadfinder.intel.com/scripts-df/support_intel.asp
|
http://downloadfinder.intel.com/scripts-df/support_intel.asp
|
||||||
@ -40,73 +53,75 @@ Driver Configuration Parameters
|
|||||||
The default value for each parameter is generally the recommended setting,
|
The default value for each parameter is generally the recommended setting,
|
||||||
unless otherwise noted.
|
unless otherwise noted.
|
||||||
|
|
||||||
Rx Descriptors: Number of receive descriptors. A receive descriptor is a data
|
Rx Descriptors: Number of receive descriptors. A receive descriptor is a data
|
||||||
structure that describes a receive buffer and its attributes to the network
|
structure that describes a receive buffer and its attributes to the network
|
||||||
controller. The data in the descriptor is used by the controller to write
|
controller. The data in the descriptor is used by the controller to write
|
||||||
data from the controller to host memory. In the 3.0.x driver the valid
|
data from the controller to host memory. In the 3.x.x driver the valid range
|
||||||
range for this parameter is 64-256. The default value is 64. This parameter
|
for this parameter is 64-256. The default value is 64. This parameter can be
|
||||||
can be changed using the command
|
changed using the command:
|
||||||
|
|
||||||
ethtool -G eth? rx n, where n is the number of desired rx descriptors.
|
ethtool -G eth? rx n, where n is the number of desired rx descriptors.
|
||||||
|
|
||||||
Tx Descriptors: Number of transmit descriptors. A transmit descriptor is a
|
Tx Descriptors: Number of transmit descriptors. A transmit descriptor is a data
|
||||||
data structure that describes a transmit buffer and its attributes to the
|
structure that describes a transmit buffer and its attributes to the network
|
||||||
network controller. The data in the descriptor is used by the controller to
|
controller. The data in the descriptor is used by the controller to read
|
||||||
read data from the host memory to the controller. In the 3.0.x driver the
|
data from the host memory to the controller. In the 3.x.x driver the valid
|
||||||
valid range for this parameter is 64-256. The default value is 64. This
|
range for this parameter is 64-256. The default value is 64. This parameter
|
||||||
parameter can be changed using the command
|
can be changed using the command:
|
||||||
|
|
||||||
ethtool -G eth? tx n, where n is the number of desired tx descriptors.
|
ethtool -G eth? tx n, where n is the number of desired tx descriptors.
|
||||||
|
|
||||||
Speed/Duplex: The driver auto-negotiates the link speed and duplex settings by
|
Speed/Duplex: The driver auto-negotiates the link speed and duplex settings by
|
||||||
default. Ethtool can be used as follows to force speed/duplex.
|
default. Ethtool can be used as follows to force speed/duplex.
|
||||||
|
|
||||||
ethtool -s eth? autoneg off speed {10|100} duplex {full|half}
|
ethtool -s eth? autoneg off speed {10|100} duplex {full|half}
|
||||||
|
|
||||||
NOTE: setting the speed/duplex to incorrect values will cause the link to
|
NOTE: setting the speed/duplex to incorrect values will cause the link to
|
||||||
fail.
|
fail.
|
||||||
|
|
||||||
Event Log Message Level: The driver uses the message level flag to log events
|
Event Log Message Level: The driver uses the message level flag to log events
|
||||||
to syslog. The message level can be set at driver load time. It can also be
|
to syslog. The message level can be set at driver load time. It can also be
|
||||||
set using the command
|
set using the command:
|
||||||
|
|
||||||
ethtool -s eth? msglvl n
|
ethtool -s eth? msglvl n
|
||||||
|
|
||||||
|
|
||||||
Additional Configurations
|
Additional Configurations
|
||||||
=========================
|
=========================
|
||||||
|
|
||||||
Configuring the Driver on Different Distributions
|
Configuring the Driver on Different Distributions
|
||||||
-------------------------------------------------
|
-------------------------------------------------
|
||||||
|
|
||||||
Configuring a network driver to load properly when the system is started is
|
Configuring a network driver to load properly when the system is started is
|
||||||
distribution dependent. Typically, the configuration process involves adding
|
distribution dependent. Typically, the configuration process involves adding
|
||||||
an alias line to /etc/modules.conf as well as editing other system startup
|
an alias line to /etc/modules.conf or /etc/modprobe.conf as well as editing
|
||||||
scripts and/or configuration files. Many popular Linux distributions ship
|
other system startup scripts and/or configuration files. Many popular Linux
|
||||||
with tools to make these changes for you. To learn the proper way to
|
distributions ship with tools to make these changes for you. To learn the
|
||||||
configure a network device for your system, refer to your distribution
|
proper way to configure a network device for your system, refer to your
|
||||||
documentation. If during this process you are asked for the driver or module
|
distribution documentation. If during this process you are asked for the
|
||||||
name, the name for the Linux Base Driver for the Intel PRO/100 Family of
|
driver or module name, the name for the Linux Base Driver for the Intel
|
||||||
Adapters is e100.
|
PRO/100 Family of Adapters is e100.
|
||||||
|
|
||||||
As an example, if you install the e100 driver for two PRO/100 adapters
|
As an example, if you install the e100 driver for two PRO/100 adapters
|
||||||
(eth0 and eth1), add the following to modules.conf:
|
(eth0 and eth1), add the following to modules.conf or modprobe.conf:
|
||||||
|
|
||||||
alias eth0 e100
|
alias eth0 e100
|
||||||
alias eth1 e100
|
alias eth1 e100
|
||||||
|
|
||||||
Viewing Link Messages
|
Viewing Link Messages
|
||||||
---------------------
|
---------------------
|
||||||
In order to see link messages and other Intel driver information on your
|
In order to see link messages and other Intel driver information on your
|
||||||
console, you must set the dmesg level up to six. This can be done by
|
console, you must set the dmesg level up to six. This can be done by
|
||||||
entering the following on the command line before loading the e100 driver:
|
entering the following on the command line before loading the e100 driver:
|
||||||
|
|
||||||
dmesg -n 8
|
dmesg -n 8
|
||||||
|
|
||||||
If you wish to see all messages issued by the driver, including debug
|
If you wish to see all messages issued by the driver, including debug
|
||||||
messages, set the dmesg level to eight.
|
messages, set the dmesg level to eight.
|
||||||
|
|
||||||
NOTE: This setting is not saved across reboots.
|
NOTE: This setting is not saved across reboots.
|
||||||
|
|
||||||
|
|
||||||
Ethtool
|
Ethtool
|
||||||
-------
|
-------
|
||||||
|
|
||||||
@ -114,29 +129,27 @@ Additional Configurations
|
|||||||
diagnostics, as well as displaying statistical information. Ethtool
|
diagnostics, as well as displaying statistical information. Ethtool
|
||||||
version 1.6 or later is required for this functionality.
|
version 1.6 or later is required for this functionality.
|
||||||
|
|
||||||
The latest release of ethtool can be found at:
|
The latest release of ethtool can be found from
|
||||||
http://sf.net/projects/gkernel.
|
http://sourceforge.net/projects/gkernel.
|
||||||
|
|
||||||
NOTE: This driver uses mii support from the kernel. As a result, when
|
NOTE: Ethtool 1.6 only supports a limited set of ethtool options. Support
|
||||||
there is no link, ethtool will report speed/duplex to be 10/half.
|
for a more complete ethtool feature set can be enabled by upgrading
|
||||||
|
ethtool to ethtool-1.8.1.
|
||||||
|
|
||||||
NOTE: Ethtool 1.6 only supports a limited set of ethtool options. Support
|
|
||||||
for a more complete ethtool feature set can be enabled by upgrading
|
|
||||||
ethtool to ethtool-1.8.1.
|
|
||||||
|
|
||||||
Enabling Wake on LAN* (WoL)
|
Enabling Wake on LAN* (WoL)
|
||||||
---------------------------
|
---------------------------
|
||||||
WoL is provided through the Ethtool* utility. Ethtool is included with Red
|
WoL is provided through the Ethtool* utility. Ethtool is included with Red
|
||||||
Hat* 8.0. For other Linux distributions, download and install Ethtool from
|
Hat* 8.0. For other Linux distributions, download and install Ethtool from
|
||||||
the following website: http://sourceforge.net/projects/gkernel.
|
the following website: http://sourceforge.net/projects/gkernel.
|
||||||
|
|
||||||
For instructions on enabling WoL with Ethtool, refer to the Ethtool man
|
For instructions on enabling WoL with Ethtool, refer to the Ethtool man page.
|
||||||
page.
|
|
||||||
|
|
||||||
WoL will be enabled on the system during the next shut down or reboot. For
|
WoL will be enabled on the system during the next shut down or reboot. For
|
||||||
this driver version, in order to enable WoL, the e100 driver must be
|
this driver version, in order to enable WoL, the e100 driver must be
|
||||||
loaded when shutting down or rebooting the system.
|
loaded when shutting down or rebooting the system.
|
||||||
|
|
||||||
|
|
||||||
NAPI
|
NAPI
|
||||||
----
|
----
|
||||||
|
|
||||||
@ -144,6 +157,25 @@ Additional Configurations
|
|||||||
|
|
||||||
See www.cyberus.ca/~hadi/usenix-paper.tgz for more information on NAPI.
|
See www.cyberus.ca/~hadi/usenix-paper.tgz for more information on NAPI.
|
||||||
|
|
||||||
|
Multiple Interfaces on Same Ethernet Broadcast Network
|
||||||
|
------------------------------------------------------
|
||||||
|
|
||||||
|
Due to the default ARP behavior on Linux, it is not possible to have
|
||||||
|
one system on two IP networks in the same Ethernet broadcast domain
|
||||||
|
(non-partitioned switch) behave as expected. All Ethernet interfaces
|
||||||
|
will respond to IP traffic for any IP address assigned to the system.
|
||||||
|
This results in unbalanced receive traffic.
|
||||||
|
|
||||||
|
If you have multiple interfaces in a server, either turn on ARP
|
||||||
|
filtering by
|
||||||
|
|
||||||
|
(1) entering: echo 1 > /proc/sys/net/ipv4/conf/all/arp_filter
|
||||||
|
(this only works if your kernel's version is higher than 2.4.5), or
|
||||||
|
|
||||||
|
(2) installing the interfaces in separate broadcast domains (either
|
||||||
|
in different switches or in a switch partitioned to VLANs).
|
||||||
|
|
||||||
|
|
||||||
Support
|
Support
|
||||||
=======
|
=======
|
||||||
|
|
||||||
@ -151,20 +183,24 @@ For general information, go to the Intel support website at:
|
|||||||
|
|
||||||
http://support.intel.com
|
http://support.intel.com
|
||||||
|
|
||||||
|
or the Intel Wired Networking project hosted by Sourceforge at:
|
||||||
|
|
||||||
|
http://sourceforge.net/projects/e1000
|
||||||
|
|
||||||
If an issue is identified with the released source code on the supported
|
If an issue is identified with the released source code on the supported
|
||||||
kernel with a supported adapter, email the specific information related to
|
kernel with a supported adapter, email the specific information related to the
|
||||||
the issue to linux.nics@intel.com.
|
issue to e1000-devel@lists.sourceforge.net.
|
||||||
|
|
||||||
|
|
||||||
License
|
License
|
||||||
=======
|
=======
|
||||||
|
|
||||||
This software program is released under the terms of a license agreement
|
This software program is released under the terms of a license agreement
|
||||||
between you ('Licensee') and Intel. Do not use or load this software or any
|
between you ('Licensee') and Intel. Do not use or load this software or any
|
||||||
associated materials (collectively, the 'Software') until you have carefully
|
associated materials (collectively, the 'Software') until you have carefully
|
||||||
read the full terms and conditions of the LICENSE located in this software
|
read the full terms and conditions of the file COPYING located in this software
|
||||||
package. By loading or using the Software, you agree to the terms of this
|
package. By loading or using the Software, you agree to the terms of this
|
||||||
Agreement. If you do not agree with the terms of this Agreement, do not
|
Agreement. If you do not agree with the terms of this Agreement, do not install
|
||||||
install or use the Software.
|
or use the Software.
|
||||||
|
|
||||||
* Other names and brands may be claimed as the property of others.
|
* Other names and brands may be claimed as the property of others.
|
||||||
|
Loading…
Reference in New Issue
Block a user