!11083 fix codecheck error

Merge pull request !11083 from honghecun/master
This commit is contained in:
openharmony_ci 2024-05-10 07:33:38 +00:00 committed by Gitee
commit 5389a3bcea
No known key found for this signature in database
GPG Key ID: 173E9B9CA92EEF8F

View File

@ -132,7 +132,10 @@ declare namespace hiSysEvent {
*
* @param {SysEventInfo} info - system event information to be written.
* @returns {Promise<void>} - Return Promise
* @throws {BusinessError} 401 - Parameter error. Possible causes: 1. Mandatory parameters are left unspecified. 2. Incorrect parameter types. 3. Parameter verification failed.
* @throws {BusinessError} 401 - Parameter error. Possible causes:
* 1. Mandatory parameters are left unspecified.
* 2. Incorrect parameter types.
* 3. Parameter verification failed.
* @throws {BusinessError} 11200001 - Invalid event domain.
* @throws {BusinessError} 11200002 - Invalid event name.
* @throws {BusinessError} 11200003 - Abnormal environment.
@ -152,7 +155,10 @@ declare namespace hiSysEvent {
*
* @param {SysEventInfo} info - system event information to be written.
* @param {AsyncCallback<void>} callback - callback function.
* @throws {BusinessError} 401 - Parameter error. Possible causes: 1. Mandatory parameters are left unspecified. 2. Incorrect parameter types. 3. Parameter verification failed.
* @throws {BusinessError} 401 - Parameter error. Possible causes:
* 1. Mandatory parameters are left unspecified.
* 2. Incorrect parameter types.
* 3. Parameter verification failed.
* @throws {BusinessError} 11200001 - Invalid event domain.
* @throws {BusinessError} 11200002 - Invalid event name.
* @throws {BusinessError} 11200003 - Abnormal environment.
@ -426,7 +432,10 @@ declare namespace hiSysEvent {
* @param {Watcher} watcher watch system event
* @throws {BusinessError} 201 - Permission denied. An attempt was made to read system event forbidden by permission: ohos.permission.READ_DFX_SYSEVENT.
* @throws {BusinessError} 202 - System API is not allowed called by Non-system application.
* @throws {BusinessError} 401 - Parameter error. Possible causes: 1. Mandatory parameters are left unspecified. 2. Incorrect parameter types. 3. Parameter verification failed.
* @throws {BusinessError} 401 - Parameter error. Possible causes:
* 1. Mandatory parameters are left unspecified.
* 2. Incorrect parameter types.
* 3. Parameter verification failed.
* @throws {BusinessError} 11200101 - Count of watchers is over limit.
* @throws {BusinessError} 11200102 - Count of watch rules is over limit.
* @syscap SystemCapability.HiviewDFX.HiSysEvent
@ -442,7 +451,10 @@ declare namespace hiSysEvent {
* @param {Watcher} watcher watch system event
* @throws {BusinessError} 201 - Permission denied. An attempt was made to read system event forbidden by permission: ohos.permission.READ_DFX_SYSEVENT.
* @throws {BusinessError} 202 - System API is not allowed called by Non-system application.
* @throws {BusinessError} 401 - Parameter error. Possible causes: 1. Mandatory parameters are left unspecified. 2. Incorrect parameter types. 3. Parameter verification failed.
* @throws {BusinessError} 401 - Parameter error. Possible causes:
* 1. Mandatory parameters are left unspecified.
* 2. Incorrect parameter types.
* 3. Parameter verification failed.
* @throws {BusinessError} 11200201 - The watcher does not exist.
* @syscap SystemCapability.HiviewDFX.HiSysEvent
* @systemapi hide for inner use
@ -459,7 +471,10 @@ declare namespace hiSysEvent {
* @param {Querier} querier receive query result
* @throws {BusinessError} 201 - Permission denied. An attempt was made to read system event forbidden by permission: ohos.permission.READ_DFX_SYSEVENT.
* @throws {BusinessError} 202 - System API is not allowed called by Non-system application.
* @throws {BusinessError} 401 - Parameter error. Possible causes: 1. Mandatory parameters are left unspecified. 2. Incorrect parameter types. 3. Parameter verification failed.
* @throws {BusinessError} 401 - Parameter error. Possible causes:
* 1. Mandatory parameters are left unspecified.
* 2. Incorrect parameter types.
* 3. Parameter verification failed.
* @throws {BusinessError} 11200301 - Count of query rules is over limit.
* @throws {BusinessError} 11200302 - Invalid query rule.
* @throws {BusinessError} 11200303 - Count of concurrent queriers is over limit.
@ -479,7 +494,10 @@ declare namespace hiSysEvent {
* @returns {number} return hiview receive task time.
* @throws {BusinessError} 201 - Permission denied. An attempt was made to read system event forbidden by permission: ohos.permission.READ_DFX_SYSEVENT.
* @throws {BusinessError} 202 - System API is not allowed called by Non-system application.
* @throws {BusinessError} 401 - Parameter error. Possible causes: 1. Mandatory parameters are left unspecified. 2. Incorrect parameter types. 3. Parameter verification failed.
* @throws {BusinessError} 401 - Parameter error. Possible causes:
* 1. Mandatory parameters are left unspecified.
* 2. Incorrect parameter types.
* 3. Parameter verification failed.
* @throws {BusinessError} 11200301 - Count of query rules is over limit.
* @throws {BusinessError} 11200302 - Invalid query rule.
* @throws {BusinessError} 11200304 Export frequency is over limit.
@ -497,7 +515,10 @@ declare namespace hiSysEvent {
* @returns {number} return hiview receive task time.
* @throws {BusinessError} 201 - Permission denied. An attempt was made to read system event forbidden by permission: ohos.permission.READ_DFX_SYSEVENT.
* @throws {BusinessError} 202 - System API is not allowed called by Non-system application.
* @throws {BusinessError} 401 - Parameter error. Possible causes: 1. Mandatory parameters are left unspecified. 2. Incorrect parameter types. 3. Parameter verification failed.
* @throws {BusinessError} 401 - Parameter error. Possible causes:
* 1. Mandatory parameters are left unspecified.
* 2. Incorrect parameter types.
* 3. Parameter verification failed.
* @throws {BusinessError} 11200301 - Count of query rules is over limit.
* @throws {BusinessError} 11200302 - Invalid query rule.
* @syscap SystemCapability.HiviewDFX.HiSysEvent
@ -512,7 +533,10 @@ declare namespace hiSysEvent {
* @permission ohos.permission.READ_DFX_SYSEVENT
* @throws {BusinessError} 201 - Permission denied. An attempt was made to read system event forbidden by permission: ohos.permission.READ_DFX_SYSEVENT.
* @throws {BusinessError} 202 - System API is not allowed called by Non-system application.
* @throws {BusinessError} 401 - Parameter error. Possible causes: 1. Mandatory parameters are left unspecified. 2. Incorrect parameter types. 3. Parameter verification failed.
* @throws {BusinessError} 401 - Parameter error. Possible causes:
* 1. Mandatory parameters are left unspecified.
* 2. Incorrect parameter types.
* 3. Parameter verification failed.
* @throws {BusinessError} 11200305 unsubscribe failed.
* @syscap SystemCapability.HiviewDFX.HiSysEvent
* @systemapi hide for inner use