8.9 KiB
SPIR-V Assembly language syntax
Overview
The assembly attempts to adhere the binary form as closely as possible using text names from section 3 of the SPIR-V spec.
Here is an example:
OpCapability Shader
OpMemoryModel Logical Simple
OpEntryPoint GLCompute %3 "main"
OpExecutionMode %3 LocalSize 64 64 1
OpTypeVoid %1
OpTypeFunction %2 %1
OpFunction %1 %3 None %2
OpLabel %4
OpReturn
OpFunctionEnd
A module is a sequence of instructions, separated by whitespace. An instruction is an opcode name followed by operands, separated by whitespace. Typically each instruction is presented on its own line, but the assembler does not enforce this rule.
The opcode names and expected operands are described in section 3 of the SPIR-V specification. An operand is one of:
- a literal integer: A decimal integer, or a hexadecimal integer
(indicated by a leading
0x
). - a literal floating point number.
- a literal string, surrounded by double-quotes ("). TODO: describe quoting and escaping rules.
- a named enumerated value, specific to that operand position. For example,
the
OpMemoryModel
takes a named Addressing Model operand (e.g.Logical
orPhysical32
), and a named Memory Model operand (e.g.Simple
orOpenCL
). Named enumerated values are only meaningful in specific positions, and will otherwise generate an error. - a mask expression, consisting of one or more mask enum names separated
by
|
. For example, the expressionNotNaN|NotInf|NSZ
denotes the mask which is the combination of theNotNaN
,NotInf
, andNSZ
flags. (This is supported by the assembler but not yet by the disassembler. TODO(dneto): Add disassembler support for emitting mask expressions.) - an injected immediate integer:
!<integer>
. See below.
Assignment-oriented Assembly Form
The description and examples from above describe the Canonical Assembly Form for SPIR-V assembly language.
We also define the Assignment-oriented Assembly Form, aimed at improving
the text's readability. In AAF, the <result-id>
generated by an
instruction is moved to the beginning of that instruction and followed by
an =
sign. This allows us to distinguish between variable definitions
and uses and locate value definitions more easily. So, the above example
can also be written as:
OpCapability Shader
OpMemoryModel Logical Simple
OpEntryPoint GLCompute %3 "main"
OpExecutionMode %3 LocalSize 64 64 1
%1 = OpTypeVoid
%2 = OpTypeFunction %1
%3 = OpFunction %1 None %2
%4 = OpLabel
OpReturn
OpFunctionEnd
ID Definitions & Usage
An ID definition pertains to the <result-id>
of an OpCode, and ID usage is any
input to an OpCode. All IDs are prefixed with %
. To differentiate between
defs and uses, we suggest using the second format shown in the above example.
Named IDs
The assembler also supports named IDs, or virtual IDs, which greatly improves
the readability of the assembly. The same ID definition and usage prefixes
apply. Names must begin with an character in the range [a-z|A-Z]
. The
following example will result in identical SPIR-V binary as the example above.
OpCapability Shader
OpMemoryModel Logical Simple
OpEntryPoint GLCompute %main "main"
OpExecutionMode %main LocalSize 64 64 1
%void = OpTypeVoid
%fnMain = OpTypeFunction %void
%main = OpFunction %void None %fnMain
%lbMain = OpLabel
OpReturn
OpFunctionEnd
Arbitrary Integers
Warning: Not all of the following has been implemented
When writing tests it can be useful to emit an invalid 32 bit word into the
binary stream at arbitrary positions within the assembly. To specify an
arbitrary word into the stream the prefix !
is used, this takes the form
!<integer>
. Here is an example.
OpCapability !0x0000FF00
Any word in a valid assembly program may be replaced by !<integer>
-- even
words that dictate how the rest of the instruction is parsed. Consider, for
example, the following assembly program:
%4 = OpConstant %1 123 456 789 OpExecutionMode %2 LocalSize 11 22 33
OpExecutionMode %3 InputLines
The words OpConstant
, LocalSize
, and InputLines
may be replaced by random
!<integer>
values, and the assembler will still assemble an output binary with
three instructions. It will not necessarily be valid SPIR-V, but it will
faithfully reflect the input text.
You may wonder how the assembler recognizes the instruction structure (including
instruction boundaries) in the text with certain crucial words replaced by
arbitrary integers. If, say, OpConstant
becomes a !<integer>
whose value
differs from the binary representation of OpConstant
(remember that this
feature is intended for fine-grain control in SPIR-V testing), the assembler
generally has no idea what that value stands for. So how does it know there is
exactly one <id>
and three number literals following in that instruction,
before the next one begins? And if LocalSize
is replaced by an arbitrary
!<integer>
, how does it know to take the next three words (instead of zero or
one, both of which are possible in the absence of certainty that LocalSize
provided)? The answer is a simple rule governing the parsing of instructions
with !<integer>
in them:
When a word in the assembly program is a !<integer>
, that integer value is
emitted into the binary output, and parsing proceeds differently than before:
each subsequent word not recognized as an OpCode is emitted into the binary
output without any checking; when a recognizable OpCode is eventually
encountered, it begins a new instruction and parsing returns to normal. (If a
subsequent OpCode is never found, then this alternate parsing mode handles all
the remaining words in the program. If a subsequent OpCode is in an
assignment form, the ID preceding it begins a new
instruction.)
The assembler processes the words encountered in alternate parsing mode as follows:
- If the word is a number literal, it outputs that number as one or more words, as defined in the SPIR-V specification for Literal Number.
- If the word is a string literal, it outputs a sequence of words representing the string as defined in the SPIR-V specification for Literal String.
- If the word is an ID, it outputs the ID's internal number. If no such number exists yet, a unique new one will be generated. (Uniqueness is at the translation-unit level: no other ID in the same translation unit will have the same number.)
- If the word is another
!<integer>
, it outputs that integer. - Any other word causes the assembler to quit with an error.
Note that this has some interesting consequences, including:
-
When an OpCode is replaced by
!<integer>
, the integer value should encode the instruction's word count, as specified in the physical-layout section of the SPIR-V specification. -
Consecutive instructions may have their OpCode replaced by
!<integer>
and still produce valid SPIR-V. For example,!262187 %1 %2 "abc" !327739 %1 %3 6 %2
will successfully assemble into SPIR-V declaring a constant and a PrivateGlobal variable. -
Enums (such as
DontInline
orSubgroupMemory
, for instance) are not handled by the alternate parsing mode. They must be replaced by!<integer>
for successful assembly. -
The
<result-id>
on the left-hand side of an assignment cannot be a!<integer>
. But it can be a number prefixed by%
, which still gives the user control over its value. -
The
=
sign cannot be processed by the alternate parsing mode if the OpCode following it is a!<integer>
. -
When replacing a named ID with
!<integer>
, it is possible to generate unintentionally valid SPIR-V. If the integer provided happens to equal a number generated for an existing named ID, it will result in a reference to that named ID being output. This may be valid SPIR-V, contrary to the presumed intention of the writer.
Notes
- Some enumerants cannot be used by name, because the target instruction
in which they are meaningful take an ID reference instead of a literal value.
For example:
- Named enumerated value
CmdExecTime
from section 3.30 Kernel Profiling Info is used in constructing a mask value supplied as an ID forOpCaptureEventProfilingInfo
. But no other instruction has enough context to bring the enumerant names from section 3.30 into scope. - Similarly, the names in section 3.29 Kernel Enqueue Flags are used to construct a value supplied as an ID to the Flags argument of OpEnqueueKernel.
- Similarly for the names in section 3.25 Memory Semantics.
- Similarly for the names in section 3.27 Scope.
- Named enumerated value
- Some enumerants cannot be used by name, because they only name values
returned by an instruction:
- Enumerants from 3.12 Image Channel Order name possible values returned
by the
OpImageQueryOrder
instruction. - Enumerants from 3.13 Image Channel Data Type name possible values
returned by the
OpImageQueryFormat
instruction.
- Enumerants from 3.12 Image Channel Order name possible values returned
by the