While the adding and removing of data from this global linked list
was guarded, GetInstanceProcAddr & GetDeviceProcAddr did not have
such guards. This results in race conditions that were detected with
thread sanitizer. This commit adds a mutex solely for the
loader.instances global variable.
There was a small issue with the initial version of the portability
enumeration extension where the portability enumeration flag bit would
be passed down to ICDs which did not expect flags to contain anything
other than zero.
While an argument could be made for those drivers to ignore flags they
do not recognize, just like extensions and other 'unknown' things, it
is best to play nice as this is the first instance creation flag bit
added.
Many tests were using the V6 TestICD, which means that it exports the
EnumerateAdapterPhysicalDevices. The loader then only looks for devices
using that functionality and if the test didn't set it up, the driver
won't have its devices found.
Also:
* Cleaned up handle_validation_tests
* Added WSI setup helpers, which put all the setup code for WSI in one place
* Created a to/from_nondispatch_handle function for TestICD, probably should
be in a more general location
Enable /W4 errors on MSVC and fix all corresponding errors.
Refactor the CMakeLists.txt to allow for compiling with clang-cl. This required
figuring out that -Wall -Wextra mangle the set of warnings used. The solution
is to use /W4 instead when compiling with clang-cl on Windows.
The sorting algorithm needed to take into account both the application
API version as well as the driver API version.
This required additional changes to the sorting algorithm for the fallback
since even if the instance supports the extension or Vulkan 1.1, the individual
drivers may not.
Also, add supporting tests which would catch these cases in the future.
In the process, I realized we assumed that the presence of an extension in the
test_icd indicated "enablement" which was incorrect. So I separated out
that into a set of "enabled instance extensions"
The physical device terminator was missing the ICD index in the
non-sorted path. This caused crashes in Angle before it was realized
that the sorting code was unintentionally disabled in that build
path.
Also, add tests to catch this case in the future in the WSI code, but
this required converting all the TEST_F tests to TEST since Gtest
didn't like mixing the 2 on my system.
Finally, fix a few WSI error messages in the loader which were
missing spaces.
Fixes#863 for non-sorting paths
The loader trampoline previously would query all devices every time
vkEnumeratePhysicalDevices was called.
To do this, it would make two calls every time:
- First, it would ignore the passed in user values
- Second, it would query the total number of available devices.
- Third, it would query the values for every available device
This resulted in layers reporting 2 vkEnumeratePhysicalDevices call for
every 1 the application made which could get very polluted in output.
It didn't break any functionality, just made things messy.
This change removes that behavior and adds a bunch of test cases to verify
nothing broke in the move.
Add tests for unknown device functions queried with both vkGetDeviceProcAddr
and vkGetInstanceProcAddr. Also loops enough times to exhaust the available
unknown function supply.
Had to fix the vk_layerGetPhysicalDeviceProcAddr in TestLayer to make the tests
pass.
MacOS currently skips tests which use vkGetInstanceProcAddr. This is due to the
need for unknown functions being lower priority and so do not warrent the time
needed to write the assembly necessary to resolve the issue fully.
Add 2 tests to verify that physical devices supporting instance
and device extensions (which are really physical device extensions)
are properly handled.
The VK_MAKE_API_VERSION macro and the VK_API_VERSION_1_X macros are better to
use. This commit switches the tests over to the non-deprecated versions of the
macros.
The loader ICD ordering could be random on Linux based on using readdir
to find ICD manifest files. This can result in random behaviors as
applications that select only the first device can switch which device is
used. To resolve this, we now sort based on device type and then
internally to the types based on PCI bus information.
This also introduces a VK_LOADER_DEFAULT_DEVICE environment variable
that can be used to force a specific PCI device. This environment variable
is actually a duplicate of the MESA_VK_DEVICE_SELECT variable, which is
also looked for if the loader environment variable is not found.
Note, that at least one ICD must support it for the extension to be used at all.
So we only do the sorting if one ICD supports it.
Fixes part of #657
Simplified the WSI tests so that they don't actually create the
platform surfaces and attach them. Instead, the test_icd framework
allows us to simply provide a dummy. This allows the tests to work
in the regresssion framework. Because of this, removed the separate
test_wsi test and merged it into test_regression.
Fixed several compiler warnings from my previous change as well.
Fix some loader terminator functions for instance physical device
functions (that were pre-Vulkan 1.1). At that point in the API, we
didn't treat VkPhysicalDevices like VkDevices. Now, you must first
query the device for extension support for even VkPhysicalDevice calls.
Back then, the loader had to emulate the functionality.
Added tests to validate many of these functions.
When handle wrapping is performed in a layer, the loader would provide the incorrect
instance handles after the recent handle validation changes. This was exposed by
RenderDoc.
Also add several tests to catch this case.
Basic tests which just makes sure the trampoline + terminator pass the data
through correctly. Data only originates from TestICD, TestLayer has no
support for the extension.
Warnings/fixes include:
* strcpy/strncpy/wstrcpy
* Dropping static on inline functions
* Use localtime_s
* Name shadowing
* Use wcstombs_s
* 32<->64 bit int conversion
* Silence spurious C4996 generated in vs2015
Made InstanceWrapper and DeviceWrapper simpler to use by moving them to test_environment
then making the Create() member functions and doing the gtest assertions in the function
itself.
Additionally:
Removed the `detail` namespace in the test_environment.
Renamed get_new_test_icd/layer to just `reset_icd/layer`. This is clearer about what it
is doing and makes the interface more expressive with code such as
`env->reset_icd().SetMinInterfaceVersion(5);`
Add support for tests which use device groups by adding a new structure that
holds pointes to PhysicalDevice structs and implementing the necessary vulkan
API calls.
This commit also:
- Formats test_icd.cpp
- Makes vk_icdGetPhysicalDeviceProcAddr return stuff by refactoring the
instance procaddr functions
Requires adding ability for device to return functions with
vkGetDeviceProcAddr that aren't necessarily useable functions.
Also added checks to make sure that the handle passed in by the loader
to the TestICD is the 'right handle' where necessary, as some functions
do not need to know which device is being called on, just that it is correct.
Functions needed in the various layer interface versions are now
exported as well as guarded behind macros configurable from CMake.
The export_definitions folder was populated as well.
Change-Id: Iebfdd8ae02062eb81b8aa9f705885c9384c95be9
This replaces instances of `#ifdef MACRO_NAME` with `#if MACRO_NAME` as now
MACRO_NAME will have a value of 0 or 1, instead of it being defined or not
defined.
Change-Id: I27a4330511a0f0d779f41851fe816fc79e868de2
The TestICD is a configurable ICD which can recreate much of the
behavior the loader expects of an ICD. Combined with a direct line
of communication between the tests and TestICD, tests can setup
specific conditions that have a known response from the loader,
thus allowing proper regression testing.
Change-Id: I84303f0ddb6011fc1b76dad25fd249abb2da29c9