winspool: Use the backend for EnumMonitors.

This commit is contained in:
Detlef Riekenberg 2008-06-30 21:54:57 +02:00 committed by Alexandre Julliard
parent 2f08621d62
commit 0848be6a60

View File

@ -762,98 +762,6 @@ static inline DWORD set_reg_szW(HKEY hkey, const WCHAR *keyname, const WCHAR *va
return ERROR_FILE_NOT_FOUND;
}
/*****************************************************************************
* enumerate the local monitors (INTERNAL)
*
* returns the needed size (in bytes) for pMonitors
* and *lpreturned is set to number of entries returned in pMonitors
*
*/
static DWORD get_local_monitors(DWORD level, LPBYTE pMonitors, DWORD cbBuf, LPDWORD lpreturned)
{
HKEY hroot = NULL;
HKEY hentry = NULL;
LPWSTR ptr;
LPMONITOR_INFO_2W mi;
WCHAR buffer[MAX_PATH];
WCHAR dllname[MAX_PATH];
DWORD dllsize;
DWORD len;
DWORD index = 0;
DWORD needed = 0;
DWORD numentries;
DWORD entrysize;
entrysize = (level == 1) ? sizeof(MONITOR_INFO_1W) : sizeof(MONITOR_INFO_2W);
numentries = *lpreturned; /* this is 0, when we scan the registry */
len = entrysize * numentries;
ptr = (LPWSTR) &pMonitors[len];
numentries = 0;
len = sizeof(buffer)/sizeof(buffer[0]);
buffer[0] = '\0';
/* Windows creates the "Monitors"-Key on reboot / start "spooler" */
if (RegCreateKeyW(HKEY_LOCAL_MACHINE, MonitorsW, &hroot) == ERROR_SUCCESS) {
/* Scan all Monitor-Registry-Keys */
while (RegEnumKeyExW(hroot, index, buffer, &len, NULL, NULL, NULL, NULL) == ERROR_SUCCESS) {
TRACE("Monitor_%d: %s\n", numentries, debugstr_w(buffer));
dllsize = sizeof(dllname);
dllname[0] = '\0';
/* The Monitor must have a Driver-DLL */
if (RegOpenKeyExW(hroot, buffer, 0, KEY_READ, &hentry) == ERROR_SUCCESS) {
if (RegQueryValueExW(hentry, DriverW, NULL, NULL, (LPBYTE) dllname, &dllsize) == ERROR_SUCCESS) {
/* We found a valid DLL for this Monitor. */
TRACE("using Driver: %s\n", debugstr_w(dllname));
}
RegCloseKey(hentry);
}
/* Windows returns only Port-Monitors here, but to simplify our code,
we do no filtering for Language-Monitors */
if (dllname[0]) {
numentries++;
needed += entrysize;
needed += (len+1) * sizeof(WCHAR); /* len is lstrlenW(monitorname) */
if (level > 1) {
/* we install and return only monitors for "Windows NT x86" */
needed += (lstrlenW(envname_x86W) +1) * sizeof(WCHAR);
needed += dllsize;
}
/* required size is calculated. Now fill the user-buffer */
if (pMonitors && (cbBuf >= needed)){
mi = (LPMONITOR_INFO_2W) pMonitors;
pMonitors += entrysize;
TRACE("%p: writing MONITOR_INFO_%dW #%d\n", mi, level, numentries);
mi->pName = ptr;
lstrcpyW(ptr, buffer); /* Name of the Monitor */
ptr += (len+1); /* len is lstrlenW(monitorname) */
if (level > 1) {
mi->pEnvironment = ptr;
lstrcpyW(ptr, envname_x86W); /* fixed to "Windows NT x86" */
ptr += (lstrlenW(envname_x86W)+1);
mi->pDLLName = ptr;
lstrcpyW(ptr, dllname); /* Name of the Driver-DLL */
ptr += (dllsize / sizeof(WCHAR));
}
}
}
index++;
len = sizeof(buffer)/sizeof(buffer[0]);
buffer[0] = '\0';
}
RegCloseKey(hroot);
}
*lpreturned = numentries;
TRACE("need %d byte for %d entries\n", needed, numentries);
return needed;
}
/******************************************************************
* monitor_unload [internal]
*
@ -7328,67 +7236,28 @@ emA_cleanup:
* Success: TRUE
* Failure: FALSE and in pcbNeeded the Bytes required for buffer, if cbBuf is too small
*
* NOTES
* Windows reads the Registry once and cache the Results.
*
*| Language-Monitors are also installed in the same Registry-Location but
*| they are filtered in Windows (not returned by EnumMonitors).
*| We do no filtering to simplify our Code.
*
*/
BOOL WINAPI EnumMonitorsW(LPWSTR pName, DWORD Level, LPBYTE pMonitors,
DWORD cbBuf, LPDWORD pcbNeeded, LPDWORD pcReturned)
{
DWORD needed = 0;
DWORD numentries = 0;
BOOL res = FALSE;
TRACE("(%s, %d, %p, %d, %p, %p)\n", debugstr_w(pName), Level, pMonitors,
cbBuf, pcbNeeded, pcReturned);
if (pName && (lstrlenW(pName))) {
FIXME("for Server %s not implemented\n", debugstr_w(pName));
SetLastError(ERROR_ACCESS_DENIED);
goto emW_cleanup;
}
if ((backend == NULL) && !load_backend()) return FALSE;
/* Level is not checked in win9x */
if (!Level || (Level > 2)) {
WARN("level (%d) is ignored in win9x\n", Level);
SetLastError(ERROR_INVALID_LEVEL);
goto emW_cleanup;
return FALSE;
}
if (!pcbNeeded) {
SetLastError(RPC_X_NULL_REF_POINTER);
goto emW_cleanup;
return FALSE;
}
/* Scan all Monitor-Keys */
numentries = 0;
needed = get_local_monitors(Level, NULL, 0, &numentries);
/* we calculated the needed buffersize. now do the error-checks */
if (cbBuf < needed) {
SetLastError(ERROR_INSUFFICIENT_BUFFER);
goto emW_cleanup;
}
else if (!pMonitors || !pcReturned) {
SetLastError(RPC_X_NULL_REF_POINTER);
goto emW_cleanup;
}
/* fill the Buffer with the Monitor-Keys */
needed = get_local_monitors(Level, pMonitors, cbBuf, &numentries);
res = TRUE;
emW_cleanup:
if (pcbNeeded) *pcbNeeded = needed;
if (pcReturned) *pcReturned = numentries;
TRACE("returning %d with %d (%d byte for %d entries)\n",
res, GetLastError(), needed, numentries);
return (res);
return backend->fpEnumMonitors(pName, Level, pMonitors, cbBuf, pcbNeeded, pcReturned);
}
/******************************************************************************