CMD12's response type is R1b, which is basically a R1 plus optional
addition of the busy signal token that can be any number of bytes.
A zero value indicates card is busy and a non-zero value indicates
the card is ready for the next command.
Current implementation sends the busy signal token without sending
the R1 first. This does not break the U-Boot/Linux mmc_spi driver,
but it does not make the VxWorks driver happy.
Move the testing logic of s->stopping in the SSI_SD_RESPONSE state
a bit later, after the first byte of the card reponse is sent out,
to conform with the spec. After the busy signal token is sent, the
state should be transferred to SSI_SD_CMD.
Fixes:
|
||
---|---|---|
.. | ||