mirror of
https://github.com/xemu-project/xemu.git
synced 2024-12-24 04:46:05 +00:00
be8c9423de
I have been staring at this FIXME for years and I never knew what it meant. I finally stumbled across it! When writing to the command registers, the old value is shifted into a HOB copy of the register and the new value is written into the primary register. When reading registers, the value retrieved is dependent on the HOB bit in the CONTROL register. By setting bit 7 (0x80) in CONTROL, any register read will, if it has one, yield the HOB value for that register instead. Our code has a problem: We were using bit 7 of the DEVICE register to model this. We use bus->cmd roughly as the control register already, as it stores the value from ide_ctrl_write. Lastly, all command register writes reset the HOB, so fix that, too. Signed-off-by: John Snow <jsnow@redhat.com> |
||
---|---|---|
.. | ||
ahci.h | ||
internal.h | ||
pci.h |