Johannes Stezenbach 3fb5eac50d ASoC: sta32x: add workaround for ESD reset issue
sta32x resets and loses all configuration during ESD test.
Work around by polling the CONFA register once a second
and restore all coeffcients and registers when CONFA
changes unexpectedly.

Signed-off-by: Johannes Stezenbach <js@sig21.net>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
2011-11-14 21:36:43 +00:00
..